X-ray-free protocol for pectus deformities based on magnetic resonance imaging and a low-cost portable three-dimensional scanning device: A preliminary study

7Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

OBJECTIVES: To compare a standard protocol using chest computed tomography (CT) to a non-irradiant protocol involving a low-cost portable 3D scanner and magnetic resonance imaging (MRI) for all pectus deformities based on the Haller index (HI). METHODS: From April 2019 to March 2020, all children treated for pectus excavatum or carinatum at our institution were evaluated by chest CT, 3D scanning (iPad with Structure Sensor and Captevia-Rodin4D) and MRI. The main objectives were to compare the HI determined by CT or MRI to a derived index evaluated with 3D scanning, the external Haller index (EHI). The secondary objectives were to assess the inter-rater variability and the concordance between CT and MRI for the HI and the correction index. RESULTS: Eleven patients were evaluated. We identified a strong correlation between the HI with MRI and the EHI (Pearson correlation coefficient = 0.900; P < 0.001), with a strong concordance between a radiologist and a non-radiologist using intra-class correlation for the HI with MRI (intra-class correlation coefficient = 0.995; [0.983; 0.999]) and the EHI (intra-class correlation coefficient = 0.978; [0.823; 0.995]). We also identified a marked correlation between the HI with CT and the EHI (Pearson coefficient = 0.855; P = 0.002), with a strong inter-rater concordance (intra-class correlation coefficient = 0.975; [0.901; 0.993]), a reliable concordance between CT and MRI for the HI and the correction index (Pearson coefficient = 0.886; P = 0.033). CONCLUSIONS: Non-irradiant pectus deformity assessment is possible in clinical practice, replacing CT with MRI and 3D scanning as a possible readily-accessible monitoring tool.

Cite

CITATION STYLE

APA

Guillot, M. S., Rouchaud, A., Mounayer, C., Tricard, J., Belgacem, A., Auditeau, E., … Ballouhey, Q. (2021). X-ray-free protocol for pectus deformities based on magnetic resonance imaging and a low-cost portable three-dimensional scanning device: A preliminary study. Interactive Cardiovascular and Thoracic Surgery, 33(1), 110–118. https://doi.org/10.1093/icvts/ivab036

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free