Anisotropic Polytetrafluoroethylene Cardiovascular Conduits Spontaneously Expand in a Growing Lamb Model

4Citations
Citations of this article
9Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Insertion of conduits from the right ventricle (RV) to the pulmonary artery (PA) is a commonly used technique for repair of congenital heart defects. The vast majority of infants and children will require reoperation and/or re-intervention to replace the conduit. Some children may require multiple reoperations, with the risk of death and morbidity increasing significantly with each subsequent operation. We evaluated the feasibility and performance of a relatively novel anisotropic conduit for cardiovascular repair in the growing lamb model. Materials and Methods: Lambs were allocated into a control (n = 3) or test (n = 4, anisotropic) conduit group. Control conventional polytetrafluoroethylene (PTFE) conduits or test anisotropic expanded PTFE (ePTFE) based test conduits measuring 10–11 mm in diameter were sewn as interpositional grafts in the main pulmonary artery (MPA) and followed up to 6 months. Clinical and echocardiographic evaluations were performed monthly with hemodynamic and angiographic assessment at 3 and 6 months. Results: Control conduits did not expand, all 3 animals developed one or more adverse events including tachypnea, ascites, inappetence, lethargy, and mortality due to severe right heart failure and significantly higher peak trans-conduit gradients (48.5 ± 5.1 p = 0.02). The test conduits spontaneously expanded up to 14.8 ± 0.8 mm in diameter, no adverse events were observed in any animals and trans-conduit gradients were significantly lower (27.0 ± 8.3, p = 0.02). Conclusions: Anisotropic ePTFE conduits can be safely implanted in growing lambs with stable hemodynamics. This spontaneously expanding anisotropic conduit may represent a novel approach to congenital heart repairs that would avoid the need for reoperation or multiple operations.

Cite

CITATION STYLE

APA

Azakie, A., Carney, J. P., Lahti, M. T., Moklyak, Y., & Bianco, R. W. (2021). Anisotropic Polytetrafluoroethylene Cardiovascular Conduits Spontaneously Expand in a Growing Lamb Model. Journal of Investigative Surgery, 34(12), 1348–1354. https://doi.org/10.1080/08941939.2020.1805056

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free