Subject-ventilator synchrony during neural versus pneumatically triggered non-invasive helmet ventilation

79Citations
Citations of this article
82Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objective: Patient-ventilator synchrony during non-invasive pressure support ventilation with the helmet device is often compromised when conventional pneumatic triggering and cycling-off were used. A possible solution to this shortcoming is to replace the pneumatic triggering with neural triggering and cycling-off-using the diaphragm electrical activity (EA di). This signal is insensitive to leaks and to the compliance of the ventilator circuit. Design: Randomized, single-blinded, experimental study. Setting: University Hospital. Participants and subjects: Seven healthy human volunteers. Interventions: Pneumatic triggering and cycling-off were compared to neural triggering and cycling-off during NIV delivered with the helmet. Measurements and results: Triggering and cycling-off delays, wasted efforts, and breathing comfort were determined during restricted breathing efforts (<20% of voluntary maximum EAdi) with various combinations of pressure support (PSV) (5, 10, 20 cm H2O) and respiratory rates (10, 20, 30 breath/min). During pneumatic triggering and cycling-off, the subject-ventilator synchrony was progressively more impaired with increasing respiratory rate and levels of PSV (p < 0.001). During neural triggering and cycling-off, effect of increasing respiratory rate and levels of PSV on subject-ventilator synchrony was minimal. Breathing comfort was higher during neural triggering than during pneumatic triggering (p < 0.001). Conclusions: The present study demonstrates in healthy subjects that subject-ventilator synchrony, trigger effort, and breathing comfort with a helmet interface are considerably less impaired during increasing levels of PSV and respiratory rates with neural triggering and cycling-off, compared to conventional pneumatic triggering and cycling-off. © 2008 The Author(s).

Cite

CITATION STYLE

APA

Moerer, O., Beck, J., Brander, L., Costa, R., Quintel, M., Slutsky, A. S., … Sinderby, C. (2008). Subject-ventilator synchrony during neural versus pneumatically triggered non-invasive helmet ventilation. Intensive Care Medicine, 34(9), 1615–1623. https://doi.org/10.1007/s00134-008-1163-z

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free