Abstract

Osseointegration, the direct functional and structural connection between device and bone is influenced by multiple factors such as implant macrogeometry and surgical technique. This study investigated the effects of osseodensification drilling techniques on implant stability and osseointegration using trabecular metal (TM) and tapered-screw vent (TSV) implants in a low-density bone. Six skeletally mature sheep were used where six osteotomy sites were prepared in each of the ilia, (n = 2/technique: Regular [R] (subtractive), clockwise [CW], and counterclockwise [CCW]). One TM and one TSV implant was subsequently placed with R osteotomy sites prepared using a conventional (subtractive) drilling protocol as recommended by the implant manufacturer for low density bone. CW and CCW drilling sites were subjected to osseodensification (OD) (additive) drilling. Evaluation of insertion torque as a function of drilling technique showed implants subjected to R drilling yielded a significant lower insertion torque relative to samples implanted in OD (CW/CCW) sites (p < 0.05). Histomorphometric analysis shows that the osseodensification demonstrates significantly greater values for bone-to-implant contact (BIC) and bone area fraction occupancy (BAFO). Histological analysis shows the presence of bone remnants, which acted as nucleating surfaces for osteoblastic bone deposition, facilitating the bridging of bone between the surrounding native bone and implant surface, as well as within the open spaces of the trabecular network in the TM implants. Devices that were implanted via OD demonstrated atemporal biomechanical stability and osseointegration. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 36:2516–2523, 2018.

References Powered by Scopus

Osseointegrated titanium implants: Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man

2422Citations
N/AReaders
Get full text

Osseointegration and its experimental background

1568Citations
N/AReaders
Get full text

Effect of titanium surface roughness on proliferation, differentiation, and protein synthesis of human osteoblast‐like cells (MG63)

1035Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Relationship between primary/mechanical and secondary/biological implant stability

123Citations
N/AReaders
Get full text

The effectiveness of osseodensification drilling protocol for implant site osteotomy: A systematic review of the literature and meta-analysis

55Citations
N/AReaders
Get full text

Osseodensification –– A systematic review and qualitative analysis of published literature

45Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Alifarag, A. M., Lopez, C. D., Neiva, R. F., Tovar, N., Witek, L., & Coelho, P. G. (2018). Atemporal osseointegration: Early biomechanical stability through osseodensification. Journal of Orthopaedic Research, 36(9), 2516–2523. https://doi.org/10.1002/jor.23893

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 43

78%

Researcher 10

18%

Professor / Associate Prof. 1

2%

Lecturer / Post doc 1

2%

Readers' Discipline

Tooltip

Medicine and Dentistry 52

79%

Engineering 10

15%

Chemistry 2

3%

Agricultural and Biological Sciences 2

3%

Save time finding and organizing research with Mendeley

Sign up for free