Clinical observations of EVO-ICL implantation and changes in corneal astigmatism using a modified technique

2Citations
Citations of this article
5Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Implantable collamer lens (ICL) surgery techniques are constantly progressing. The purpose of this study was to investigate the application effect of the modified technique and its impact on the change in corneal astigmatism in EVO-ICL surgery. Methods: The analysis of retrospective cohort data included 153 eyes of 81 patients with myopia from July 2018 to May 2020. An EVO-ICL was inserted by modified surgical skills, including a single 3.0 mm corneal incision and no ophthalmic viscosurgical device (OVD) before the insertion of the ICL (modified technique group: 41 cases, 80 eyes) and standard procedure (standard technique group: 40 cases, 73 eyes). Early postoperative intraocular pressure (IOP) was monitored at 2 and 24 h. IOP, corrected distance visual acuity (CDVA), uncorrected distance visual acuity (UDVA), vault, and anterior chamber depth (ACD) were measured 1, 6, and 12 months following the initial examination. The corneal endothelial cell density (ECD) was monitored at 6 and 12 months after the operation. Surgically induced astigmatism (SIA) in the total, anterior, and posterior corneal surfaces was analysed 1 month after the operation. Results: No serious complications were detected. The two groups had no difference in visual outcomes, ICL vaults, or ACD at any time point (P > 0.05). Two hours postoperatively, IOP was significantly lower in the modified technique group (16.22 ± 2.22 vs. 18.37 ± 1.92 mmHg, P < 0.05) than in the standard technique group. IOP decreased gradually after 24 h to preoperative levels. The postoperative IOP remained stable over a 12-month period. The ECD at 6 and 12 months was not significantly different between the groups (P > 0.05). SIA in the total, anterior, and posterior corneal surfaces were assumed to have no clinically meaningful differences between groups at one month after operation (P > 0.05). Conclusions: The modified technique is efficient and safe, producing comparable visual and structural outcomes without adversely affecting ECD, and reduces fluctuations in IOP at the early postoperative stages. The auxiliary incision in the standard technique does not increase corneal SIA, which is also a factor to consider for inexperienced surgeons.

Cite

CITATION STYLE

APA

Wang, Y., Yang, R., Huang, Y., Zhang, C., Liu, H., Jia, Z., & Zhao, S. (2022). Clinical observations of EVO-ICL implantation and changes in corneal astigmatism using a modified technique. BMC Ophthalmology, 22(1). https://doi.org/10.1186/s12886-022-02603-8

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free