Target alignment in the Shen-Guang II Upgrade laser facility

21Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

The Shen-Guang II Upgrade (SG-II-U) laser facility consists of eight high-power nanosecond laser beams and one short-pulse picosecond petawatt laser. It is designed for the study of inertial confinement fusion (ICF), especially for conducting fast ignition (FI) research in China and other basic science experiments. To perform FI successfully with hohlraum targets containing a golden cone, the long-pulse beam and cylindrical hohlraum as well as the short-pulse beam and cone target alignment must satisfy tight specifications (30 and 20 µm rms for each case). To explore new ICF ignition targets with six laser entrance holes (LEHs), a rotation sensor was adapted to meet the requirements of a three-dimensional target and correct beam alignment. In this paper, the strategy for aligning the nanosecond beam based on target alignment sensor (TAS) is introduced and improved to meet requirements of the picosecond lasers and the new six LEHs hohlraum targets in the SG-II-U facility. The expected performance of the alignment system is presented, and the alignment error is also discussed.

Cite

CITATION STYLE

APA

Ren, L., Shao, P., Zhao, D., Zhou, Y., Cai, Z., Hua, N., … Lin, Z. (2018). Target alignment in the Shen-Guang II Upgrade laser facility. High Power Laser Science and Engineering, 6. https://doi.org/10.1017/hpl.2018.4

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free