Strong Negative Interference by Calcium Dobesilate in Sarcosine Oxidase Assays for Serum Creatinine Involving the Trinder Reaction

19Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

Abstract

The vasoprotective drug calcium dobesilate is known to interfere with creatinine (Cr) quantifications in sarcosine oxidase enzymatic (SOE) assays. The aim of this study was to investigate this interference in 8 different commercially available assays and to determine its clinical significance. In in vitro experiments, interference was evaluated at 3 Cr levels. For this, Cr was quantified by SOE assays in pooled serum supplemented with calcium dobesilate at final concentrations of 0, 2, 4, 8, 16, 32, and 64μg/mL. Percent bias was calculated relative to the drug-free specimen. For in vivo analyses, changes in serum concentrations of Cr, cystatin C (CysC; a renal function marker), and calcium dobesilate were monitored in healthy participants of group I before and after oral calcium dobesilate administration. In addition, variations in interference were also examined among different SOE assays using serum obtained from healthy participants of group II. Lastly, Cr levels from the 10 patients treated with calcium dobesilate were measured using 4 SOE assays and liquid chromatography-isotope dilution tandem mass spectrometry (LC-IDMS/MS) for comparison. Our in vitro analyses indicated that the presence of 8μg/mL calcium dobesilate resulted in a -4.4% to -36.3% reduction in Cr serum concentration compared to drug-free serum for 8 SOE assays examined. In vivo, Cr values decreased relative to the baseline level with increasing drug concentration, with the lowest Cr levels obtained at 2 or 3hours after drug administration in participants of group I. The observed Cr concentrations for participants in group II were reduced by -28.5% to -3.1% and -60.5% to -11.6% at 0 and 2hours after administration related to baseline levels. The Cr values of 10 patients measured by Roche, Beckman, Maker, and Merit Choice SOE assays showed an average deviation of -20.0%, -22.4%, -14.2%, and -29.6%, respectively, compared to values obtained by LC-IDMS/MS. These results revealed a clinically significant negative interference with calcium dobesilate in all sarcosine oxidase-based Cr assays, but the degree of interference varied greatly among the assays examined. Thus, extra care should be taken in evaluating Cr quantification obtained by SOE assays in patients undergoing calcium dobesilate therapy.

Cite

CITATION STYLE

APA

Guo, X., Hou, L., Cheng, X., Zhang, T., Yu, S., Fang, H., … Qiu, L. (2015). Strong Negative Interference by Calcium Dobesilate in Sarcosine Oxidase Assays for Serum Creatinine Involving the Trinder Reaction. Medicine (United States), 94(23), e905. https://doi.org/10.1097/MD.0000000000000905

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free