The effect of limiting the range of perimetric sensitivities on pointwise assessment of visual field progression in glaucoma

51Citations
Citations of this article
38Readers
Mendeley users who have this article in their library.

Abstract

PURPOSE. Automated perimetry does not produce reliable estimates of true psychophysical threshold in glaucomatous visual fields when the perimetric threshold falls below 15 to 19 dB. It may be possible to truncate testing at such locations and not use stimuli with very high contrast. However, this can only be recommended if it does not harm the ability to monitor change. This study examined the effect of applying such a cutoff by censoring sensitivities in two existing longitudinal datasets. METHODS. Series of six visual fields were taken from participants with glaucoma or high-risk ocular hypertension in the Portland Progression Project (P3) and Rotterdam Eye Study (RES). Pointwise linear regression was used to find “progressing” locations, defined as a slope ≤—1 dB/y with P < 1%. An eye was labeled progressing if ≥3 locations were progressing. This was repeated after setting any sensitivities below the cutoff value C (CdB) to instead equal that value for different integer values of CdB. RESULTS. In the P3 cohort tested using Swedish Interactive Testing Algorithm (SITA) Standard, censoring below 15 to 19 dB did not reduce the number of eyes flagged as progressing. For the RES cohort tested using the Full Threshold algorithm, censoring below 10 dB did not reduce the number of eyes flagged as progressing, but a modest reduction was seen for CdB between 10 dB and 15 to 19 dB. CONCLUSIONS. The proportion of eyes flagged as progressing was not decreased by censoring unreliable sensitivities. Restricting the range of contrast used in clinical perimetry may be possible without hampering the ability to monitor glaucomatous visual field progression.

Author supplied keywords

References Powered by Scopus

The primate retina contains two types of ganglion cells, with high and low contrast sensitivity

611Citations
N/AReaders
Get full text

A framework for comparing structural and functional measures of glaucomatous damage

595Citations
N/AReaders
Get full text

A new generation of algorithms for computerized threshold perimetry, SITA

357Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Detection and measurement of clinically meaningful visual field progression in clinical trials for glaucoma

147Citations
N/AReaders
Get full text

The value of visual field testing in the era of advanced imaging: clinical and psychophysical perspectives

72Citations
N/AReaders
Get full text

Clinical Evaluation of Swedish Interactive Thresholding Algorithm–Faster Compared With Swedish Interactive Thresholding Algorithm–Standard in Normal Subjects, Glaucoma Suspects, and Patients With Glaucoma

53Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Gardiner, S. K., Swanson, W. H., & Demirel, S. (2016). The effect of limiting the range of perimetric sensitivities on pointwise assessment of visual field progression in glaucoma. Investigative Ophthalmology and Visual Science, 57(1), 288–294. https://doi.org/10.1167/iovs.15-18000

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 12

55%

Researcher 6

27%

Professor / Associate Prof. 3

14%

Lecturer / Post doc 1

5%

Readers' Discipline

Tooltip

Medicine and Dentistry 11

61%

Nursing and Health Professions 3

17%

Computer Science 2

11%

Neuroscience 2

11%

Save time finding and organizing research with Mendeley

Sign up for free