Resistance of MAX 6325 reference voltage source on operating temperature variation

1Citations
Citations of this article
1Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The article presents the problem of the Zener diode based reference voltage sources resistance to changes in operating temperature. The test stand, measurement methodology and results are presented. Reference voltage sources are crucial elements of analog-to-digital systems. They set the standard to which the measured voltage is compared to. Therefore, the stability of their work is critical for many areas of precision metrology.

Cite

CITATION STYLE

APA

Nowak, P., Juś, A., & Szewczyk, R. (2015). Resistance of MAX 6325 reference voltage source on operating temperature variation. Advances in Intelligent Systems and Computing, 352, 189–196. https://doi.org/10.1007/978-3-319-15835-8_21