Improved cerebrospinal fluid suppression for intracranial vessel wall MRI

31Citations
Citations of this article
48Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To develop and assess a three-dimensional (3D) high resolution black blood MRI (BBMRI) method for evaluation of intracranial vessels with improved cerebrospinal fluid (CSF) suppression. Materials and Methods: The anti-driven-equilibrium (ADE) pulse was incorporated into a variable flip-angle TSE-based 3D BBMRI to improve CSF suppression. ADE-BBMRI was optimized in 8 participants and compared with BBMRI, with acquired 0.5 mm isotropic resolution and scan time of 5.4 min at 3 Tesla. Contrast-enhanced ADE-BBMRI protocol was implemented in nine patients with intracranial atherosclerosis. Signal and morphological measurements were compared between ADE-BBMRI and BBMRI, as well as pre- and postcontrast ADE-BBMRI. Reliability was assessed by intraclass correlations (ICC). Results: ADE-BBMRI effectively suppressed the surrounding CSF signal of intracranial vessels, with a 36–44% reduction compared with BBMRI. ADE-BBMRI also reduced the overall wall signal by 8–8.5%, but provided a significant improvement in wall-to-CSF contrast-to-noise ratio over BBMRI (middle cerebral artery, 5.93 ± 0.59 versus 3.95 ± 1.67, P < 0.01; basilar artery, 3.8 ± 1.76 versus 1.34 ± 0.54, P = 0.01, respectively). No differences were noted in morphological measurements between ADE-BBMRI and BBMRI (lumen area, 6.35 ± 2.87 versus 6.32 ± 2.84 mm2; wall area, 1.28 ± 0.52 versus 1.27 ± 0.53 mm2; mean wall thickness, 0.93 ± 0.30 versus 0.93 ± 0.32 mm; maximum wall thickness, 1.27 ± 0.33 versus 1.28 ± 0.36 mm, all P > 0.05). Contrast enhanced ADE-BBMRI improved the plaque delineation by the increased wall signal, wall-to-CSF and wall-to-blood contrast-to-noise ratio. ICC ranged from 0.54 to 0.95. Conclusion: The 3D ADE-BBMRI provides excellent blood and CSF suppression, and accurate measurements of intracranial vessels at 0.5 mm isotropic resolution in 5 min. Its clinical application may provide insight into stroke risk. J. Magn. Reson. Imaging 2016;44:665–672.

Cite

CITATION STYLE

APA

Yang, H., Zhang, X., Qin, Q., Liu, L., Wasserman, B. A., & Qiao, Y. (2016). Improved cerebrospinal fluid suppression for intracranial vessel wall MRI. Journal of Magnetic Resonance Imaging, 44(3), 665–672. https://doi.org/10.1002/jmri.25211

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free