Comparison of proximally versus distally placed spatially distributed sequential stimulation electrodes in a dynamic knee extension task

  • Laubacher M
  • Aksöz E
  • Binder-Macleod S
  • et al.
N/ACitations
Citations of this article
35Readers
Mendeley users who have this article in their library.

Abstract

Spatially distributed sequential stimulation (SDSS) has demonstrated substantial power output and fatigue benefits compared to single electrode stimulation (SES) in the application of functional electrical stimulation (FES). This asymmetric electrode setup brings new possibilities but also new questions since precise placement of the electrodes is one critical factor for good muscle activation. The aim of this study was to compare the power output, fatigue and activation properties of proximally versus distally placed SDSS electrodes in an isokinetic knee extension task simulating knee movement during recumbent cycling. M. vastus lateralis and medialis of seven able-bodied subjects were stimulated with rectangular bi-phasic pulses of constant amplitude of 40 mA and at an SDSS frequency of 35 Hz for 6 min on both legs with both setups (i.e. n=14). Torque was measured during knee-extension movement by a dynamometer at an angular velocity of 110 deg/s. Mean power, peak power and activation time were calculated and compared for the initial and final stimulation phases, together with an overall fatigue index. Power output values (Pmean, Ppeak) were scaled to a standardised reference input pulse width of 100 μs (P mean,s, P peak,s). The initial evaluation phase showed no significant differences between the two setups for all outcome measures. P peak and P peak,s were both significantly higher in the final phase for the distal setup (25.4 ± 8.1 W vs. 28.2 ± 6.2 W, p=0.0062 and 34.8 ± 9.5 W vs. 38.9 ± 6.7 W, p=0.021, respectively). With distal SDSS, there was modest evidence of higher P mean and P mean,s (p=0.071, p=0.14, respectively) but of longer activation time (p=0.096). The rate of fatigue was similar for both setups. For practical FES applications, distal placement of the SDSS electrodes is preferable.

Cite

CITATION STYLE

APA

Laubacher, M., Aksöz, E. A., Binder-Macleod, S., & Hunt, K. J. (2016). Comparison of proximally versus distally placed spatially distributed sequential stimulation electrodes in a dynamic knee extension task. European Journal of Translational Myology, 26(2). https://doi.org/10.4081/ejtm.2016.6016

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free