Flow cytometry analysis with a new FITC-conjugated monoclonal antibody-3E12 for HLA-B*57:01 rapid screening in prevention of abacavir hypersensitivity in HIV-1-infected patients

5Citations
Citations of this article
18Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Rapid screening for the detection of HLA-B*57:01 in the prevention of abacavir hypersensitivity in HIV-1-infected patients is a hallmark for clinical services. Objective: The aim of this work was to analyze the utility of flow cytometry with a new FITC-conjugated B-17 monoclonal antibody (mAb3E12) for HLA-B*57:01 screening in a Spanish cohort of 577 HIV-1+ individuals. Methods: Cryopreserved peripheral blood mononuclear cell samples from HIV-1+ individuals were analyzed by flow cytometry with the mAb 3E12 that recognizes both HLA-B*57 and HLA-B*58 alleles (members of the group specificity, HLA-B17). Patients' DNA samples had been previously typed for HLA-B*57:01 with PCR-SSO or PCR-SSP and additional DNA sequencing (EPI Study). The results obtained by flow cytometry were compared with the results obtained by the DNA-PCR techniques. Results: By flow cytometry, 46 samples (7.97%) were positive for HLA-B17, 530 (91.86%) were negative, and 1 (0.17%) was undetermined. All samples found negative by flow cytometry were negative for HLA-B*57:01 by DNA-PCR. Of the HLA-B17 positive samples, 31 (67.4%) were positive for HLA-B*57:01, 2 (3.25%) were positive for HLA-B*57:03, 11 (26.1%) were positive for HLA-B*58, and 2 (3.25%) were negative for both HLA-B*57 and HLA-B*58 antigens. The undetermined sample was negative for HLA-B*57 and HLA-B*58 alleles by DNA-PCR. Conclusions: This study shows that flow cytometry with mAb3E12 is a highly sensitive method (no false negatives) to implement prior to DNA-PCR analysis for rapid screening of HLA-B*57:01. Additional confirmation by molecular HLA typing method would be required in less than 10% of the cohort of HIV-1-infected individuals. © 2013 Thomas Land Publishers, Inc.

Cite

CITATION STYLE

APA

Rodríguez-Sáinz, C., Valor, L., Hernández, D., Gil, J., Carbone, J., Pascual-Bernaldez, M., … Fernández-Cruz, E. (2013). Flow cytometry analysis with a new FITC-conjugated monoclonal antibody-3E12 for HLA-B*57:01 rapid screening in prevention of abacavir hypersensitivity in HIV-1-infected patients. HIV Clinical Trials, 14(4), 160–164. https://doi.org/10.1310/hct1404-160

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free