Comparison between thrombelastography and thromboelastometry in hyperfibrinolysis detection during adult liver transplantation

81Citations
Citations of this article
73Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background Hyperfibrinolysis is one of the main causes of non-surgical bleeding during liver transplantation (LT). Viscoelastic haemostatic assays, including thromboelastometry (ROTEM®) and thrombelastography (TEG®), can detect hyperfibrinolysis at the bedside. No study has yet demonstrated which device or assay is more suitable for detecting hyperfibrinolysis. Methods This prospective observational study compared ROTEM® and TEG® in isolated adult LT. ROTEM® (EXTEM® [tissue factor activation], FIBTEM® [tissue factor activation with platelet inhibition], and APTEM® [tissue factor activation with tranexamic acid/aprotinin]) and TEG® (kaolin-TEG®) were simultaneously performed using arterial blood samples at eight time-points during LT: induction of general anaesthesia, 60 min after skin incision, 10 and 45 min after portal vein clamp, 15 min before graft reperfusion, and five, 30, and 90 min after graft reperfusion. Hyperfibrinolysis was identified per the manufacturers' definitions (maximum lysis >15% in ROTEM® or Lysis30>8% in TEG®) and confirmed with APTEM®; incidence was compared between assays McNemar's test. Results Among 296 possible measurement points from 376 consecutive LT recipients, 250 underwent final analysis: 46 measurement points were excluded because of missing assays or flat line. Hyperfibrinolysis was confirmed at 89 (36%) of 250 measurement points: FIBTEM®, EXTEM®, and kaolin-TEG® detected 84 (94%), 41 (46%), and 21 (24%) hyperfibrinolysis, respectively. These hyperfibrinolysis detection rates significantly differed from each other (P<0.001). Conclusions Tissue factor-triggered ROTEM® tests were more sensitive than contact-activated k-TEG® in identifying hyperfibrinolysis in LT patients. Inhibition of platelet-fibrin interaction in FIBTEM® enhanced sensitivity to hyperfibrinolysis detection compared with EXTEM®.

References Powered by Scopus

The incidence and magnitude of fibrinolytic activation in trauma patients

409Citations
N/AReaders
Get full text

Platelets synthesize large amounts of active plasminogen activator inhibitor 1

194Citations
N/AReaders
Get full text

Systemic effects of tissue plasminogen activator-associated fibrinolysis and its relation to thrombin generation in orthotopic liver transplantation

188Citations
N/AReaders
Get full text

Cited by Powered by Scopus

The use of viscoelastic haemostatic assays in the management of major bleeding: A British Society for Haematology Guideline

171Citations
N/AReaders
Get full text

The role of evidence-based algorithms for rotational thromboelastometry-guided bleeding management

164Citations
N/AReaders
Get full text

Concepts and Controversies in Haemostasis and Thrombosis Associated with Liver Disease: Proceedings of the 7th International Coagulation in Liver Disease Conference

152Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Abuelkasem, E., Lu, S., Tanaka, K., Planinsic, R., & Sakai, T. (2016). Comparison between thrombelastography and thromboelastometry in hyperfibrinolysis detection during adult liver transplantation. British Journal of Anaesthesia, 116(4), 507–512. https://doi.org/10.1093/bja/aew023

Readers over time

‘16‘17‘18‘19‘20‘21‘22‘23‘24‘2505101520

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 17

53%

Researcher 11

34%

Professor / Associate Prof. 3

9%

Lecturer / Post doc 1

3%

Readers' Discipline

Tooltip

Medicine and Dentistry 43

90%

Agricultural and Biological Sciences 2

4%

Business, Management and Accounting 2

4%

Veterinary Science and Veterinary Medic... 1

2%

Save time finding and organizing research with Mendeley

Sign up for free
0