Technical note: Evaluation of interval between measurements and calculation method for the quantification of enteric methane emissions measured by respiration chamber

4Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

Abstract

Respiration chambers share one analyzer working in parallel, and methane (CH4) concentrations have to be measured at certain intervals. The maximum and minimum values in the kinetics of CH4 emissions can be missed during the interval between measurements, which may influence the quantification of CH4 emissions. Chambers must be opened for morning feeding and cleaning, which causes a loss of CH4 data. Calculation methods are needed to estimate the lost CH4 emission data, which may influence the estimated amount of daily CH4 emissions. In this study, we measured the CH4 emissions of 10 growing Chinese Holstein dairy heifers in respiration chambers. Methane concentrations were measured every 0.5 min to obtain the 23-h kinetics of CH4 emissions, which were further selected at different intervals between measurements (i.e., 5, 30, 60, 120, 180, and 240 min) to evaluate the effects of interval on quantification of CH4 emissions. The missing 1-h kinetics of CH4 emissions before feeding were not measured, and 2 calculation methods were used to estimate the missing 1-h kinetics of CH4 emissions: mean value of measuring period (the mean method) and the nearest value of measurement just before chamber opening (the nearest method). The results showed that the rates of CH4 emission from 10 heifers varied from 4.56 to 11.42 g/h. The increment of intervals decreased maximum rate of CH4 emission and increased minimum rate of CH4 emission. Interval caused less than 5% of the difference in measuring CH4 emissions. Although the mean method had greater estimated daily CH4 emission than the nearest method, the difference was within 3%. The interval between measurements (≤3 h) and calculation method had little influence on enteric CH4 emission measurements.

Cite

CITATION STYLE

APA

Wang, R., Wang, M., Zhang, X. M., Yang, H. M., Wen, J. N., Ma, Z. Y., … Tan, Z. L. (2019). Technical note: Evaluation of interval between measurements and calculation method for the quantification of enteric methane emissions measured by respiration chamber. Journal of Dairy Science, 102(7), 6242–6247. https://doi.org/10.3168/jds.2019-16245

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free