The impact of the resonance tube on performance of a thermoacoustic stack

15Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

Abstract

This paper presents a study of the impact of the resonance tube on performance of a thermoacoustic stack. The resonance tube is a key component of a standing-wave thermoacoustic refrigerator. The appropriated resonance tube's length leads to an increase of performance of the stack in terms of the temperature difference. The results also indicate that the optimal operating frequency differs from the design based on the equation of a half-wavelength. The resonance tube length is elongated to compensate for some effects that occur in the resonance tube, especially when the stack is placed in the resonance tube. The relationship of these parameters is necessary to the design and measurement performance of the thermoacoustic refrigeration system.

Cite

CITATION STYLE

APA

Wantha, C., & Assawamartbunlue, K. (2011). The impact of the resonance tube on performance of a thermoacoustic stack. Frontiers in Heat and Mass Transfer, 2(4), 1–8. https://doi.org/10.5098/hmt.v2.4.3006