Quantitative, temperature-calibrated and real-time glucose biosensor based on symmetrical-meandering-type resistor and intertwined capacitor structure

10Citations
Citations of this article
7Readers
Mendeley users who have this article in their library.

Abstract

Here, we propose a glucose biosensor with the advantages of quantification, excellent linearity, temperature-calibration function, and real-time detection based on a resistor and capacitor, in which the resistor works as a temperature sensor and the capacitor works as a biosensor. The resistor has a symmetrical meandering type structure that increases the contact area, leading to variations in resistance and effective temperature monitoring of a glucose solution. The capacitor is designed with an intertwined structure that fully contacts the glucose solution, so that capacitance is sensitively varied, and high sensitivity monitoring can be realized. Moreover, a polydimethylsiloxane microfluidic channel is applied to achieve a fixed shape, a fixed point, and quantitative measurements, which can eliminate influences caused by fluidity, shape, and thickness of the glucose sample. The glucose solution in a temperature range of 25–100◦C is measured with variations of 0.2716 Ω/◦C and a linearity response of 0.9993, ensuring that the capacitor sensor can have reference temperature information before detecting the glucose concentration, achieving the purpose of temperature cali-bration. The proposed capacitor-based biosensor demonstrates sensitivities of 0.413 nF/mg·dL−1, 0.048 nF/mg·dL−1, and 0.011 pF/mg·dL−1; linearity responses of 0.96039, 0.91547, and 0.97835; and response times less than 1 second, respectively, at DC, 1 kHz, and 1 MHz for a glucose solution with a concentration range of 25–1000 mg/dL.

References Powered by Scopus

Chronic Adipose Tissue Inflammation Linking Obesity to Insulin Resistance and Type 2 Diabetes

694Citations
N/AReaders
Get full text

Wearable non-invasive epidermal glucose sensors: A review

481Citations
N/AReaders
Get full text

Mechanism of development of atherosclerosis and cardiovascular disease in diabetes mellitus

358Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Advanced Self-Powered Biofuel Cells with Capacitor and Nanogenerator for Biomarker Sensing

8Citations
N/AReaders
Get full text

Recent Advances in Multiplexed Wearable Sensor Platforms for Real-Time Monitoring Lifetime Stress: A Review

7Citations
N/AReaders
Get full text

Microfluidic Bio-Sensors and Their Applications

3Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Ma, Y., Qiang, T., Gao, M., Liang, J., & Jiang, Y. (2021). Quantitative, temperature-calibrated and real-time glucose biosensor based on symmetrical-meandering-type resistor and intertwined capacitor structure. Biosensors, 11(12). https://doi.org/10.3390/bios11120484

Readers over time

‘22‘23‘2402468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 1

50%

Researcher 1

50%

Readers' Discipline

Tooltip

Biochemistry, Genetics and Molecular Bi... 1

100%

Article Metrics

Tooltip
Social Media
Shares, Likes & Comments: 1

Save time finding and organizing research with Mendeley

Sign up for free
0