Heater’s pipes are used as a media for heating of fluids or changing of their ofphase from liquid to vapor/gas. Rupture of these pipes may cause all systems inthe production process stopand the high economic losses. This study aims toavoid the cases to accur in the future.Visual inspection, macrography, microstructure, hardness test and SEM-EDAXexamination were the methods applied in this study. It was known that the piperuptured atthe 6 o'clock area, the hardness value of which was identical to thematerial tensile strength (476 MPa), conforming to the standard specification andthe same indication was also indicated from the microstructure of the normalferrite-pearlite phase. At atemperature of about 390 C and traces of wall thinningin around 4:30 to 7:30, the pipes ruptured due to the thin walls could notwithstand the internal pressure of the pipe . The thinking occurred because thewater-level in the heater’s pipes was to low,resulting in cavitation of vaporbubbles on the inside surface of pipe wall.Keywords: Pipe, rupture, thin-wall, water-level, temperature, cavitation.AbstrakPipa heater digunakan sebagai media untuk memanaskan fluida atau untukmerubah fase dari cair menjadi uap/gas. Pecahnya pipa dapat menyebabkansemua sistim dalam proses produksi akan menjadi berhenti dan potensi kerugiansecara ekonomi tinggi. Penelitian ini bertujuan untuk menghindari kasuskerusakan yang serupa dimasa mendatang.Pemeriksaan visual, makrografi, struktur mikro, uji kekerasan dan pemeriksaanSEM dan EDAX merupakan metode yang diterapkan dalam penelitian ini.Diketahui bahwa pipa pecah pada area jam 6,nilai kekerasan yang identik dengankekuatan tarik material (476 MPa) masih di atas standar spesifikasi dan indikasiyang sama juga ditunjukkan dari struktur mikro yaitu fase ferit – pearlit normal.Dengan suhu sekitar 390 C dan jejak penipisan dinding di sekitar 4:30-7:30,sehingga pecahnya pipa karena dinding tipis tidak bisa menahan tekanan dalampipa dan penipisan terjadi disebabkan air tingkat di pemanas pipa terlalu rendah,sehingga mengakibatkan kavitasi gelembung uap pada permukaan dalam dindingpipa.Kata Kunci : Pipa, pecah, dinding tipis, tingkat-air, temperatur, kapitasi.
CITATION STYLE
. S., & Syahril, M. (2019). ANALISA KERUSAKAN PIPA PEMANAS AIR UNTUK UAP PEMBANGKIT LISTRIK = FAILURE ANALYSIS OF WATER HEATER PIPE FOR STEAM GENERATOR. Material Komponen Dan Konstruksi, 14(2). https://doi.org/10.29122/mkk.v14i2.1659
Mendeley helps you to discover research relevant for your work.