Temporary hemiepiphysiodesis using an eight‐plate implant for coronal angular deformity around the knee in children aged less than 10 years: efficacy, complications, occurrence of rebound and risk factors

20Citations
Citations of this article
40Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Temporary hemiepiphysiodesis (TH) using an eight-Plate implant is one of the most common surgeries used for the correction of coronal angular deformities around the knee in adolescents. However, few studies have focused on children aged less than 10 years treated with TH using an eight-Plate implant. The purpose of this study was to investigate the efficacy, correction velocity, and complications of TH with an eight-Plate implant as well as the occurrence of rebound and risk factors in this population. Methods: This retrospective study included a total of 135 physes (101 knees) from 66 children (mean age of 4.69 years old, range from 1 to 10 years old) who underwent TH with an eight-Plate implant to correct coronal genu angular deformities in our hospital. Related clinical factors were recorded and analysed by multivariable linear and logistic regression models. Results: The mean deformity correction period was 13.26 months, and the mean follow-up after eight-Plate removal was 12.71 months. In all, 94.06% (95/101 knees) of the genu angular deformities were completely corrected. Non-idiopathic genu angular deformity was found to be an independent risk factor for deformity correction failure (odds ratio (OR) = 2.47). The femoral correction velocity was significantly higher than the tibial correction velocity (1.28° vs. 0.83° per month, p < 0.001). After adjustment for other factors, younger children had higher correction velocities in the distal femur; however, genu valgum and idiopathic deformities were associated with higher correction velocities in the proximal tibia. In addition, we found three (3/101, 2.97%) knees with genu valgum that experienced rebound after removal of the eight-Plate, while five (5/101, 4.95%) knees with non-idiopathic genu angular deformity experienced screw loosening. No other complications were found, and non-idiopathic deformity was the only risk factor for complications (OR = 3.96). No risk factor was found for rebound in our study. Conclusions: TH using an eight-Plate implant is an effective procedure for coronal genu angular deformities with a low incidence of complications and rebound in patients younger than 10 years old. For this population, TH using an eight-Plate should be considered as soon as the deformity stops responding to conservative treatments. The parents of children younger than 10 years of age with non-idiopathic deformities should be informed preoperatively that the deformity may be prone to correction failure or screw loosening after eight-Plate implantation.

Cite

CITATION STYLE

APA

Dai, Z. Z., Liang, Z. P., Li, H., Ding, J., Wu, Z. K., Zhang, Z. M., & Li, H. (2021). Temporary hemiepiphysiodesis using an eight‐plate implant for coronal angular deformity around the knee in children aged less than 10 years: efficacy, complications, occurrence of rebound and risk factors. BMC Musculoskeletal Disorders, 22(1). https://doi.org/10.1186/s12891-020-03915-w

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free