Purpose: Either SENSE+CG or POCS-ICE methods can be used to correct for motion-induced phase errors in navigator-free multishot diffusion imaging. SENSE+CG has the advantage of a fast convergence, however, occasionally the convergence can be unstable, thus degrading the image quality. POCS-ICE has a stable convergence and can be used with a high number of shots, but its convergence is slow, which limits its practical usage. The study here proposes an improved method based on both SENSE+CG and POCS-ICE, called Phase-updated Regularized SENSE (PR-SENSE), for navigator-free multishot diffusion imaging. Theory and Methods: In PR-SENSE, a total variation regularization method is used to solve the SENSE inverse problem instead of the conjugate gradient method used in SENSE+CG. This method is implemented by using a lagged diffusivity fixed point iteration algorithm. Additionally, the phase is updated during the iteration process to improve the image accuracy. Results: Simulations and in vivo experiments demonstrated that PR-SENSE can successfully correct for the motion-induced phase errors in multi-shot DWI. It integrates the advantages of SENSE+CG and POCS-ICE, resulting in a fast and stable convergence with improved image quality. Conclusion: Given its advantages, PR-SENSE is a significant improvement over other methods for navigator-free high-resolution DWI. Magn Reson Med 78:172–181, 2017. © 2016 International Society for Magnetic Resonance in Medicine.
CITATION STYLE
Hu, Z., Ma, X., Truong, T. K., Song, A. W., & Guo, H. (2017). Phase-updated regularized SENSE for navigator-free multishot diffusion imaging. Magnetic Resonance in Medicine, 78(1), 172–181. https://doi.org/10.1002/mrm.26361