Exergy and Exergoenvironmental Analysis of a CCHP System Based on a Parallel Flow Double-Effect Absorption Chiller

7Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

A combined cooling, heating, and power (CCHP) system which produces electricity, heating, and cooling is modeled and analyzed. This system is comprised of a gas turbine, a heat recovery steam generator, and a double-effect absorption chiller. Exergy analysis is conducted to address the magnitude and the location of irreversibilities. In order to enhance understanding, a comprehensive parametric study is performed to see the effect of some major design parameters on the system performance. These design parameters are compressor pressure ratio, gas turbine inlet temperature, gas turbine isentropic efficiency, compressor isentropic efficiency, and temperature of absorption chiller generator inlet. The results show that exergy efficiency of the CCHP system is higher than the power generation system and the cogeneration system. In addition, the results indicate that when waste heat is utilized in the heat recovery steam generator, the greenhouse gasses are reduced when the fixed power output is generated. According to the parametric study results, an increase in compressor pressure ratio shows that the network output first increases and then decreases. Furthermore, an increase in gas turbine inlet temperature increases the system exergy efficiency, decreasing the total exergy destruction rate consequently.

References Powered by Scopus

District heating and cooling: Review of technology and potential enhancements

559Citations
N/AReaders
Get full text

Energy, environment and sustainable development

274Citations
N/AReaders
Get full text

Exergoenvironmental analysis and optimization of a cogeneration plant system using Multimodal Genetic Algorithm (MGA)

217Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Energy, exergy, environmental and economic analysis of an agricultural waste-to-energy integrated multigeneration thermal power plant

118Citations
N/AReaders
Get full text

A natural gas-based eco-friendly polygeneration system including gas turbine, sorption-enhanced steam methane reforming, absorption chiller and flue gas CO<inf>2</inf> capture unit

28Citations
N/AReaders
Get full text

Investigation of the effects of operating parameters of an internal combustion engine on the performance and fuel consumption of a CCHP system

26Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Mousafarash, A. (2016). Exergy and Exergoenvironmental Analysis of a CCHP System Based on a Parallel Flow Double-Effect Absorption Chiller. International Journal of Chemical Engineering, 2016. https://doi.org/10.1155/2016/2370305

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 8

62%

Professor / Associate Prof. 2

15%

Researcher 2

15%

Lecturer / Post doc 1

8%

Readers' Discipline

Tooltip

Engineering 9

69%

Energy 3

23%

Decision Sciences 1

8%

Save time finding and organizing research with Mendeley

Sign up for free