Turbulent kinetic energy in the ascending aorta is greater in bicuspid than tricuspid aortic valve stenosis

  • Loudon M
  • Bissell M
  • Dyverfeldt P
  • et al.
N/ACitations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: The main determinant of the haemodynamic significance of aortic stenosis (AS) is the irreversible pressure loss that is created by the stenosis. The majority of the pressure loss is caused by conversion/ dissipation of turbulent kinetic energy (TKE) to heat. Recent developments in cardiac magnetic resonance 4D flow imaging have allowed the non-invasive assessment of TKE. Bicuspid aortic valve disease is known to be associated with a larger ascending aorta and disordered flow patterns, and we hypothesised that peak TKE would be higher in bicuspid AS than tricuspid AS. Methods: 15 patients with bicuspid AS (mean age 63.6 years; mean aortic valve area 1.4cm2; mean dimension of the ascending aorta at the level of the pulmonary artery 3.9cm) and no more than mild other valve disease were compared with 22 patients with tricuspid AS (mean age 72.9 years; mean aortic valve area 1.2cm2; mean dimension of the ascending aorta at the level of the pulmonary artery 3.2cm) and no more than mild other valve disease. All subjects underwent time resolved, three dimensional cine magnetic resonance flow imaging at 3 Tesla, for the assessment of peak TKE. The peak TKE was obtained by integrating the TKE per voxel across the ascending aorta at each time frame of the cardiac cycle. Results: On visual inspection, the highest TKE was seen at valvular level and dispersed centrally in tricuspid AS. In bicuspid AS the highest TKE is seen at valvular level, then as a jet hitting the wall of the proximal aorta, before dispersing (see Figure 1). Peak TKE was significantly higher in the bicuspid AS patients compared to tricuspid AS patients (see table). Conclusions: Bicuspid AS is associated with significantly higher peak TKE compared with tricuspid AS of comparable severity. This applies both when including the valve, and when measured in the ascending aorta alone, and may result from the larger aorta and disordered flow patterns typically seen in bicuspid AS. This implies that bicuspid AS may be associated with a greater haemodynamic burden for similar degrees of stenosis. (Figure Presented).

Cite

CITATION STYLE

APA

Loudon, M., Bissell, M. M., Dyverfeldt, P., Carlhall, C. J., Ebbers, T., Hess, A. T., … Myerson, S. G. (2015). Turbulent kinetic energy in the ascending aorta is greater in bicuspid than tricuspid aortic valve stenosis. Journal of Cardiovascular Magnetic Resonance, 17, O88. https://doi.org/10.1186/1532-429x-17-s1-o88

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free