Autocapture compatibility in patients with the MembraneEX lead and Affinity pulse generators

13Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The first Autocapture generation worked well with all recommended leads. The newer Autocapture generation provides a more sensitive resolution for evoked response testing and its implementation in a dual-chamber device. The purpose of the study was to evaluate the performance of the Affinity SR/DR pacemaker with the new Autocapture algorithm in combination with the small surface area pacing lead MembraneEX in 129 patients. Autocapture ventricular threshold, sensing threshold, lead impedance, evoked response (ER) and polarization signals were determined at implantation and discharge, as well as after 1 and 3 months. Autocapture recommendation rate was based on the ER sensitivity test. The median pacing threshold was 0.38, 0.50, 0.75, 0.75 V at implant, discharge, 1 and 3 months post-implant, respectively. The respective data for median lead impedance were 744, 605, 649 and 691 ohms; median sensing threshold was 12.5 mV at all visits. The median ER amplitude was 9.0, 10.1 9.9 and 10.1 mV and the median polarization signal 0.39 mV at all visits. The frequency of recommended Autocapture activation was 98.3%, 99.2%, 98.3% and 96.2% of all patients at implant, at discharge, 1 and 3 months post-implant respectively. In conclusion, the studied pulse generator enabled, in combination with this pacing lead, in >95% of all patients activation of Autocapture.

References Powered by Scopus

Early complications of permanent pacemaker implantation: No difference between dual and single chamber systems

220Citations
N/AReaders
Get full text

Complications related to permanent pacemaker therapy

211Citations
N/AReaders
Get full text

Automatic adjustment of pacemaker stimulation output correlated with continuously monitored capture thresholds: A multicenter study

118Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Role of ventricular autocapture function in increasing longevity of DDDR pacemakers: A prospective study

50Citations
N/AReaders
Get full text

Automatic adjustment of pacing output in the clinical setting

41Citations
N/AReaders
Get full text

Evolution of pacing for bradycardia: Autocapture

25Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Schuchert, A., Voitk, J., Liu, B., Kolk, R., Stammwitz, E., & Beiras, J. (2001). Autocapture compatibility in patients with the MembraneEX lead and Affinity pulse generators. Europace, 3(4), 332–335. https://doi.org/10.1053/eupc.2001.0181

Readers over time

‘12‘15‘20‘2100.511.52

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 2

50%

Professor / Associate Prof. 1

25%

Researcher 1

25%

Readers' Discipline

Tooltip

Medicine and Dentistry 1

33%

Business, Management and Accounting 1

33%

Neuroscience 1

33%

Save time finding and organizing research with Mendeley

Sign up for free
0