Ready for OR or not? human reader supplements Eyesi scoring in cataract surgical skills assessment

14Citations
Citations of this article
48Readers
Mendeley users who have this article in their library.

Abstract

To compare the internal computer-based scoring with human-based video scoring of cataract modules in the Eyesi virtual reality intraocular surgical simulator, a comparative case series was conducted at the Department of Clinical Sciences - Ophthalmology, Lund University, Skåne University Hospital, Malmö, Sweden. Methods: Seven cataract surgeons and 17 medical students performed one video-recorded trial with each of the capsulorhexis, hydromaneuvers, and phacoemulsifcation divide-and-conquer modules. For each module, the simulator calculated an overall score for the performance ranging from 0 to 100. Two experienced masked cataract surgeons analyzed each video using the Objective Structured Assessment of Cataract Surgical Skill (OSACSS) for individual models and modified Objective Structured Assessment of Surgical Skills (OSATS) for all three modules together. The average of the two assessors' scores for each tool was used as the video-based performance score. The ability to discriminate surgeons from naïve individuals using the simulator score and the video score, respectively, was compared using receiver operating characteristic (ROC) curves. Results: The ROC areas for simulator score did not differ from 0.5 (random) for hydromaneuvers and phacoemulsifcation modules, yielding unacceptably poor discrimination. OSACSS video scores all showed good ROC areas signifcantly different from 0.5. The OSACSS video score was also superior compared to the simulator score for the phacoemulsifcation procedure: ROC area 0.945 vs 0.664 for simulator score (P = 0.010). Corresponding values for capsulorhexis were 0.887 vs 0.761 (P = 0.056) and for hydromaneuvers 0.817 vs 0.571 (P = 0.052) for the video scores and simulator scores, respectively.The ROC area for the combined procedure was 0.938 for OSATS video score and 0.799 for simulator score (P=0.072). Conclusion: Video-based scoring of the phacoemulsifcation procedure was superior to the innate simulator scoring system in distinguishing cataract surgical skills. Simulator scoring rendered unacceptably poor discrimination for both the hydromaneuvers and the phacoemulsi-fcation divide-and-conquer module. Our results indicate a potential for improvement in Eyesi internal computer-based scoring. © 2013 Selvander and Åsman.

Cite

CITATION STYLE

APA

Selvander, M., & Åsman, P. (2013). Ready for OR or not? human reader supplements Eyesi scoring in cataract surgical skills assessment. Clinical Ophthalmology, 7, 1973–1977. https://doi.org/10.2147/OPTH.S48374

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free