Toward standardization of cardiac troponin 1 measurements part II: Assessing commutability of candidate reference materials and harmonization of cardiac troponin I assays

86Citations
Citations of this article
35Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Cardiac tropoin I (cTnI) measurements show an ∼20- to 40-fold difference between assays, and better standardization and harmonization are needed. Toward this goal, the AACC cTnI Standardization Committee collaborated with the National Institute of Standards and Technology (NIST) in an earlier study to select 2 candidate reference materials (cRMs). Methods: Two troponin cRMs, a teoponin C-troponin I-troponin T (CIT) complex from human heart tissue and a CIT complex from recombinant technology, were supplied to NIST for assessment of composition and purity, and cTnI value assignment. These cRMs and 6 cTnI-positive human serum pools were shipped to manufacturers of 15 cTnI assays. Commutability of the materials was examined by determining the numerical relationship for the cRM preparations between each manufacturer-specified field method and each of the other 14 field methods. These relationships were then compared with the corresponding numerical relationships for the human serum pools. Harmonization of methods was accomplished by determining regression parameters relative to the analytical system yielding values closest to the median for each serum pool. These regression parameters were used to recalculate pool values to harmonize the assays. Interassay CVs before and after harmonization were determined. Results: Characterization of the CIT and CI cRMs showed that these materials were of specified composition. The proportion of cTnI methods that demonstrated commutability for the CIT cRM was 45%; for the CI cRM, 39% of methods demonstrated commutability. Interassay cTnI variability for the field methods ranged from 82% to 97%, median 88%. After harmonization, variability of the serum pools for the cTnI methods was decreased to between 9.0% and 23%, median 15.5%. Conclusions: The proportion of methods demonstrating commutability was too low for use as a common calibrator for the cTnI field methods. However a simple strategy using serum pools can improve harmonization of field cTnI methods by more than 5-fold. The CIT cRM was selected by the AACC cTnI standardization committee, and a new lot has been classified as the cTnI certified reference material Standard Reference Material 2921 by NIST. © 2006 American Association for Clinical Chemistry.

Cite

CITATION STYLE

APA

Christenson, R. H., Duh, S. H., Apple, F. S., Bodor, G. S., Bunk, D. M., Panteghini, M., … Kahn, S. E. (2006). Toward standardization of cardiac troponin 1 measurements part II: Assessing commutability of candidate reference materials and harmonization of cardiac troponin I assays. Clinical Chemistry, 52(9), 1685–1692. https://doi.org/10.1373/clinchem.2006.068437

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free