Evaluation of an apparatus to be combined with a smartphone for the early detection of spinal deformities

17Citations
Citations of this article
47Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Mobile smartphones are equipped with inclinometers enabling them to acquire angular clinical measures. The Scolioscreen has been developed in conjunction with a smartphone APP to enable the measure of the angle of trunk inclination (ATI) thus offering a convenient and reliable means to measure and screen for spinal deformities. The objective was to compare the reliability and accuracy of a Scolioscreen-smartphone combination, a smartphone alone, and a Scoliometer, for measuring the angle of trunk inclination in spinal deformities under blinded conditions for intra- and inter-observer analyses.Methods: A cohort of 39 patients with adolescent idiopathic scoliosis were recruited. Each had maximum ATI measured by 3 observers: attending spine surgeon, nurse, and parent presenting with patient. Two series of measurements were performed by each observer using Scolioscreen-smartphone, smartphone alone and Scoliometer. Intra-class correlation coefficients (ICC) from two-way mixed model based on absolute agreement were used to assess intra- and inter-observer reliability as well as consistency between measurement techniques.Results: Intra- and inter-observer reliability for measuring maximum ATI was 0.94-0.89 with Scolioscreen-smartphone, decreased to 0.89-0.75 for smartphone alone, and was 0.95- 0.89 for Scoliometer. Considering Scoliometer measurement taken by surgeon the gold standard, there was excellent consistency with measurements from Scolioscreen-smartphone taken by surgeon (ICC = 0.99), nurse (ICC = 0.95), and parent (ICC = 0.91). Conversely, consistency decreased when surgeon (ICC = 0.86), nurse (ICC = 0.86) and parent (ICC = 0.85) used smartphone alone.Conclusion: Study shows the Scolioscreen-smartphone to overcome limitations associated with ATI measurements using smartphones alone. The Scolioscreen-smartphone provides a reliability and consistency similar to the gold standard (use of Scoliometer by spine surgeon) and enables a parent to take reliable measurements on their own thus offering an accessible and convenient tool for all to use. © 2014 Driscoll et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Driscoll, M., Fortier-Tougas, C., Labelle, H., Parent, S., & Mac-Thiong, J. M. (2014). Evaluation of an apparatus to be combined with a smartphone for the early detection of spinal deformities. Scoliosis, 9(1). https://doi.org/10.1186/1748-7161-9-10

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free