Right ventricular pacing increases risk of appropriate implantable cardioverter-defibrillator shocks asymmetrically: An analysis of the ALTITUDE database

13Citations
Citations of this article
38Readers
Mendeley users who have this article in their library.

Abstract

Background: Right ventricular pacing (RVP) increases risk of atrial fibrillation in patients with implantable cardioverter-defibrillators (ICDs), but ventricular proarrhythmia is less clear. We analyzed a large remote monitoring database to assess this question. Methods and Results: Patients with single-or dual-chamber ICDs, engaged in remote monitoring for at least 6 months and with unchanged tachycardia programming, were included. %RVP was derived for each weekly transmission. ICD electrograms preceding the first shock were adjudicated. Among 425 625 transmissions received from 8435 patients, 389 appropriate shocks occurred over a mean follow-up of 15.0±8.8 months. In a time-dependent Cox proportional hazards model, transmissions with 80% to 98% RVP were associated with a hazard ratio of 1.56 for an appropriate shock in the subsequent week compared with <1% RVP (95% CI, 1.01-2.41; P=0.04). By contrast, ≥98% RVP trended toward a lower risk of an appropriate shock (hazard ratio, 0.61; 95% CI, 0.33-1.12; P=0.108). Lifetime cumulative %RVP was closely correlated with weekly %RVP (R2=0.907) and was similarly associated with increased risk of appropriate shocks at 80% to 98% RVP (hazard ratio, 1.57; 95% CI, 1.01-2.44; P=0.046) but not at ≥98% RVP (hazard ratio, 0.49; 95% CI, 0.24-1.01; P=0.052). These results were driven by dual-chamber devices, but unaffected by PVC counts or programming. Male sex and age were also associated with appropriate ICD shocks. Conclusions: Increasing frequency of RVP is associated with a progressively increased risk of appropriate ICD shocks until ≥98% RVP. RVP may have ventricular proarrhythmia because of competition of paced and intrinsic rhythm in ICD patients.

Cite

CITATION STYLE

APA

Cronin, E. M., Jones, P., Seth, M. C., & Varma, N. (2017). Right ventricular pacing increases risk of appropriate implantable cardioverter-defibrillator shocks asymmetrically: An analysis of the ALTITUDE database. Circulation: Arrhythmia and Electrophysiology, 10(10). https://doi.org/10.1161/CIRCEP.116.004711

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free