Simulation of double effect absorption refrigeration system

2Citations
Citations of this article
2Readers
Mendeley users who have this article in their library.
Get full text

Abstract

In this study the Double effect Absorption Refrigeration system (DAR) is developed and its thermodynamic analysis is performed using different working fluid pairs. The DAR consists of a high and low temperature generator, high and low temperature absorbers, condenser, evaporator, expansion valves, mixture and refrigerant heat exchangers and pumps and it is made up of two cycles. In the DAR system, NH3/H2O is used as refrigerant/absorbent working pair at high temperature cycle and NH3/LiNO3is used a refrigerant/absorbent working pair at low temperature cycle. This system is called as System I. In order to be able to compare the effects of using different fluid pairs in these two cycles, a new system is formed. In this new system, fluid pair at the high temperature cycle remained same as before (NH3/H2O), but NH3/NaSCN is used at low temperature cycle and this new system is called as System II. While the selected results of calculations of both systems were presented in the figures, only the results of analysis of system II are tabulated in the study. The analysis of the system is performed at various operation conditions and the coefficient of performance (COP) and the high temperature circulation ratios (fH) were calculated and given graphically. Low temperature circulation ratios (fL) were also calculated but not shown in the study. A computer program is developed in FORTRAN for the simulation of the DAR and results are given graphically. The results show that the performance of the NH3/LiNO3working fluid pair has slightly better performance than NH3/NaSCN, at low temperature cycle for the same working conditions. It is also observed that COP of the double effect system is greater than the COP of single effect system. In this study, energy and exergy analyses of a two-stage heat pump-drying system are conducted, and the performance of the overall system is evaluated. The system has two cycles: a heat pump and a drying cycle. The working fluid of the heat pump and the drying cycles are R-134A and air, respectively.

Cite

CITATION STYLE

APA

Atilgan, I., & Aygun, C. (2014). Simulation of double effect absorption refrigeration system. In Progress in Sustainable Energy Technologies Vol II: Creating Sustainable Development (pp. 685–703). Springer International Publishing. https://doi.org/10.1007/978-3-319-07977-6_45

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free