Assessment of the systemic effects of budesonide inhaled from Easyhaler® and from Turbuhaler® in healthy male volunteers

8Citations
Citations of this article
20Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

The main objective of this study was to show dose-dependent equivalence in the systemic activity of budesonide 800 μg day-1 and 1600 μg day-1 delivered from either Easyhaler® or Turbuhaler® in healthy male subjects. This single-centre study was carried out according to a randomized, double-blind, double-dummy, five-way crossover design over a 9-week period. All subjects received 1 week of treatment with the following, in randomized order, with a washout week between each treatment: budesonide Easyhaler® 800 μg day-1 plus placebo Turbuhaler®; budesonide Easyhaler® 1600 μg day-1 plus placebo Turbuhaler®; placebo Easyhaler® plus Pulmicort® Turbuhaler® 800 μg day-1; placebo Easyhaler® plus Pulmicort® Turbuhaler® 1600 μg day-1; placebo Easyhaler® plus placebo Turbuhaler®. The final inhalation of study drug was performed at the study centre, where blood and urine samples were collected. Fifteen subjects were recruited and all completed the study. Mean serum cortisol AUC0-20 values (the primary outcome variable) were comparable for each device at the two dose levels, and met the defined criteria for equivalence (90% C10.8-1.25 for between-treatment difference). Budesonide 800 μg day-1 caused minimal suppression of serum cortisol AUC0-20 values. Budesonide 1600 μg day-1 statistically significantly suppressed serum cortisol AUC0-20 values compared with placebo. Mean morning serum cortisol values were within the reference range in all treatment groups. At a budesonide dose of 800 μg day-1 mean urine cortisol/creatinine ratio was statistically significantly higher with Easyhaler® than with Turbuhaler®, but there was no significant difference between the devices at the 1600 μg day-1 dose. Serum budesonide concentrations were equivalent for each device at both dose levels. Adverse drug reactions were infrequent and mild in nature and there were no clinically significant changes in laboratory safety variables. In conclusion, in healthy male volunteers, budesonide 800 μg day-1 and 1600 μg day-1 inhaled from Easyhaler® had comparable systemic effects to the same doses inhaled via Turbuhaler®. © 2001 Harcourt Publishers Ltd.

Cite

CITATION STYLE

APA

Hämäläinen, K. M., Granander, M., Toivanen, P., & Malinen, A. (2001). Assessment of the systemic effects of budesonide inhaled from Easyhaler® and from Turbuhaler® in healthy male volunteers. Respiratory Medicine, 95(11), 863–869. https://doi.org/10.1053/rmed.2001.1157

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free