In emergently ventilated trauma patients, low end-tidal CO2 and low cardiac output are associated and correlate with hemodynamic instability, hemorrhage, abnormal pupils, and death

25Citations
Citations of this article
42Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: In a smaller experience, the authors previously demonstrated that end-tidal carbon dioxide (PetCO2) and cardiac output (CO) had a positive association in emergently intubated trauma patients during Emergency Department resuscitation. The aim of this larger study was to reassess the relationship of PetCO2 with CO and identify patient risk-conditions influencing PetCO2 and CO values.Methods: The investigation consists of acutely injured trauma patients requiring emergency tracheal intubation. The study focuses on the prospective collection of PetCO2 and noninvasive CO monitor (NICOM®) values in the Emergency Department.Results: From the end of March through August 2011, 73 patients had 318 pairs of PetCO2 (mm Hg) and CO (L/min.) values. Mean data included Injury Severity Score (ISS) ≥15 in 65.2%, Glasgow Coma Score of 6.4 ± 4.6, hypotension in 19.0%, and death in 34.3%. With PetCO2 ≤ 25 (15.9 ± 8.0), systolic blood pressure was 77.0 ± 69, CO was 3.2 ± 3.0, cardiac arrest was 60.4%, and mortality was 84.9%. During hypotension, CO was lower with major blood loss (1.9), than without major loss (5.0; P = 0.0008). Low PetCO2 was associated with low CO (P < 0.0001). Low PetCO2 was associated (P ≤ 0.0012) with ISS > 20, hypotension, bradycardia, major blood loss, abnormal pupils, cardiac arrest, and death. Low CO was associated (P ≤ 0.0059) with ISS > 20, hypotension, bradycardia, major blood loss, abnormal pupils, cardiac arrest, and death.Conclusions: During emergency department resuscitation, a decline in PetCO2 correlates with decreases in noninvasive CO in emergently intubated trauma patients. Decreasing PetCO2 and declining NICOM CO are associated with hemodynamic instability, hemorrhage, abnormal pupils, and death. The study indicates that NICOM CO values are clinically discriminate and have physiologic validity. © 2013 Dunham et al.; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Dunham, C. M., Chirichella, T. J., Gruber, B. S., Ferrari, J. P., Martin, J. A., Luchs, B. A., … Merrell, R. (2013). In emergently ventilated trauma patients, low end-tidal CO2 and low cardiac output are associated and correlate with hemodynamic instability, hemorrhage, abnormal pupils, and death. BMC Anesthesiology, 13. https://doi.org/10.1186/1471-2253-13-20

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free