Reproducibility of airway responsiveness in horses using flowmetric plethysmography and histamine bronchoprovocation

23Citations
Citations of this article
47Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Inflammatory airway disease has a high prevalence in horses, but is often a diagnostic challenge. Flowmetric plethysmography and histamine bronchoprovocation (FP/HBP) is a simple and effective tool for diagnosis, but reproducibility of these measurements made over time has not been established. Hypothesis: We hypothesize that the measurement of airway responsiveness in horses using FP/HBP is consistent over both short and long periods of time. Animals: Twenty-nine healthy adult horses from 2 university herds. Methods: In this prospective experimental study, airway responsiveness was determined in each horse at day 0 (baseline [BL]) with FP/ HBP, using PC35 (provocative concentration of histamine needed to increase Dflow by 35%) as a measure of airway responsiveness. Each horse was re-tested 1-4 weeks after BL (short-term [ST]) and again at 3-12 months after BL (longterm [LT]). Results: In the ST period, 23/27 (85%) of the horses had a PC35 that was within 1 doubling concentration of histamine of their BL value, with a mean change of 0.52 doubling concentrations (95% CI 0.26-0.79, range 0-2.06). For the LT data, 19/26 (73%) of horses were within 1 doubling concentration of their BL value, with a mean change of 0.81 doubling concentrations (95% CI 0.45-1.17, range 0.14-3.10). There was no significant difference in reproducibility between the 2 groups of subjects. Conclusions and Clinical Importance: Repeated measurements of airway responsiveness obtained with FP/HBP show acceptable reproducibility over time periods up to a year. However, caution must be used when testing horses when ambient air temperature is low. © 2009 by the American College of Veterinary Internal Medicine.

References Powered by Scopus

A concordance correlation coefficient to evaluate reproducibility

6870Citations
N/AReaders
Get full text

Reliability, repeatability and reproducibility: Analysis of measurement errors in continuous variables

757Citations
N/AReaders
Get full text

Reproducibility and comparison of responses to inhaled histamine and methacholine

411Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Inflammatory Airway Disease of Horses-Revised Consensus Statement

337Citations
N/AReaders
Get full text

Recurrent airway obstruction: A review

106Citations
N/AReaders
Get full text

Owner-reported coughing and nasal discharge are associated with clinical findings, arterial oxygen tension, mucus score and bronchoprovocation in horses with recurrent airway obstruction in a field setting

33Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Nolen-Walston, R. D., Kuehn, H., Boston, R. C., Mazan, M. R., Wilkins, P. A., Bruns, S., & Hoffman, A. M. (2009). Reproducibility of airway responsiveness in horses using flowmetric plethysmography and histamine bronchoprovocation. Journal of Veterinary Internal Medicine, 23(3), 631–635. https://doi.org/10.1111/j.1939-1676.2009.0307.x

Readers over time

‘11‘12‘13‘14‘15‘16‘17‘18‘19‘20‘21‘22‘23‘24‘2502468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 12

44%

Professor / Associate Prof. 6

22%

Researcher 6

22%

Lecturer / Post doc 3

11%

Readers' Discipline

Tooltip

Veterinary Science and Veterinary Medic... 16

44%

Medicine and Dentistry 14

39%

Agricultural and Biological Sciences 5

14%

Nursing and Health Professions 1

3%

Save time finding and organizing research with Mendeley

Sign up for free
0