Illuminance in spaces is important criteria in rating building performance. These also a strategy to develop some passive design criteria to meet the occupant visual comfort. The aim of this study is to investigate the fluctuation of the illuminance level and the impact of daylighting in an optimum performance zone. This study also investigates the effects of occupant density whether affect the illuminance level in two selected office buildings. Qualitative survey has been conducted on the occupant's perception toward visual comfort and obtaining the comparison on the glare effect by using IESVE computer simulation while visual test has been conducted involving selected workers. The maximum occupant density and physical conditions; window to wall ratio of 25%, 40% and 70% of typical office space were identified by using IESVE simulation. Findings from experiment of visual performance and daylighting simulation showed more than 50% occupancy in typical office room with 70% of WWR affected the extend of the daylight zone and the acceptable of illuminance level is not achieved. There high contract between 50% of the occupancy in a room is also changed the illuminance level of more than 26%. The findings contribute towards the improvement of an acceptable visual comfort ranges and design recommendations for optimum performance zone in a single office space in Malaysia.

References Powered by Scopus

Windows, view, and office characteristics predict physical and psychological discomfort

410Citations
N/AReaders
Get full text

The 'adaptive zone'-A concept for assessing discomfort glare throughout daylit spaces

223Citations
N/AReaders
Get full text

Impact of window size and sunlight penetration on office workers' mood and satisfaction: A Novel Way of Assessing Sunlight

139Citations
N/AReaders
Get full text

Cited by Powered by Scopus

STRATEGIES IN IMPROVING THE BUILDING EFFICIENCY AND DAYLIGHTING: A CASE STUDY OF GREEN BUILDING

4Citations
N/AReaders
Get full text

Indoor constant illumination control strategy research based on natural lighting analysis

1Citations
N/AReaders
Get full text

ENHANCING ENERGY EFFICIENCY: A CASE STUDY OF LIGHTING RETROFIT SYSTEMS IN MALAYSIAN UNIVERSITY ENVIRONMENTS

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Mohd Husini, E., Raja Md Yazit, R. N. S., Arabi, F., Wan Ismail, W. N., & Jaafar, N. H. (2018). Light, daylighting and fluctuation of illuminance level in office buildings. In IOP Conference Series: Materials Science and Engineering (Vol. 401). Institute of Physics Publishing. https://doi.org/10.1088/1757-899X/401/1/012021

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 9

90%

Lecturer / Post doc 1

10%

Readers' Discipline

Tooltip

Design 6

46%

Engineering 5

38%

Energy 1

8%

Social Sciences 1

8%

Save time finding and organizing research with Mendeley

Sign up for free