The optimization of RP-HPLC condition using response surface methodology box-behnken design for simultaneous determination of metformin HCL and glimepiride in spiked plasma

3Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

Objective: Aim of this study was to develop and validate the RP-HPLC method using Box-Behnken Design (BBD) for simultaneous analysis metformin HCl and glimepiride in spiked plasma. Methods: The chromatographic system was comprised of acetonitrile-phosphate buffer 0.0125 M+Sodium Dodecyl Sulphate (SDS) 1 mmol as a mobile phase and Ascentis® Phenyl C18 (250 x 4.6 mm i.d.; 5 µm) column as a stationary phase with UV detector at 210 nm. Three independent variables included phosphate buffer (%), pH and flow rate were optimized using Box-Behnken Design. The observed responses were retention time, peak area and resolution. Results: The predicted optimum condition of the RP-HPLC system consisted of phosphate buffer solution of 72%, pH at 4.3 and flow rate at 0.8 ml/min. By using this condition, the duration of analysis was more than 18 min, so it was necessary to modify the flow rate to be 1.0 ml/min to get shorter analysis duration. This condition was then applied to analyze metformin and glimepiride in spiked plasma and validated according to the EMA guideline. AUC of interfering components at the IS retention time between 588-1092 mV, the linearity of metformin was 0.9993 and glimepiride was 0.9991, accuracy and precision were between-13.33% until 16.08%, dilution integrity and metformin stability studies were between-4.01% until 11.82%, and for glimepiride stability studies were between-37.48% until-4.76%. Conclusion: Box-Behnken Design can help optimize the HPLC system, and the optimum condition was valid to analyze metformin and glimepiride in spiked plasma by considering the storage time of plasma samples.

References Powered by Scopus

Introduction to Modern Liquid Chromatography

3314Citations
N/AReaders
Get full text

Box-Behnken design: An alternative for the optimization of analytical methods

2704Citations
N/AReaders
Get full text

An overview of experimental designs in HPLC method development and validation

297Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Microsponges-mediated targeted topical delivery of rosemary oil for hair growth promotion: optimization and in-vivo studies

3Citations
N/AReaders
Get full text

Green metrics-based HPLC method for quantification of three antidiabetic drugs in tablet dosage form using Box–Behnken design

0Citations
N/AReaders
Get full text

Response Surface Methodology for the Optimized and Validated Investigation of Ropivacaine in Bulk and Tablet Dosage form by RP – HPLC

0Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Izma, H., Martono, S., & Lukitaningsih, E. (2020). The optimization of RP-HPLC condition using response surface methodology box-behnken design for simultaneous determination of metformin HCL and glimepiride in spiked plasma. International Journal of Applied Pharmaceutics, 12(2), 24–35. https://doi.org/10.22159/ijap.2020v12i2.36052

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 5

83%

Professor / Associate Prof. 1

17%

Readers' Discipline

Tooltip

Pharmacology, Toxicology and Pharmaceut... 4

80%

Chemistry 1

20%

Save time finding and organizing research with Mendeley

Sign up for free