Comparison of surgically induced astigmatism between anterior and total cornea in 2.2 mm steep meridian incision cataract surgery

8Citations
Citations of this article
23Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: This study aimed to compare surgically induced astigmatism (SIA) on the anterior and total cornea during cataract surgery through a 2.2 mm steep meridian incision. Methods: The study included 69 left eyes of 69 patients who had undergone cataract surgery. The 69 eyes were classified into three subgroups according to the preoperative steep meridian. Following phacoemulsification, an intraocular lens was inserted into the bag. The keratometric measurements were taken 12 months postoperatively, on the anterior cornea (automated keratometer and anterior keratometry [K] from a rotating Scheimpflug camera) and total cornea (equivalent K reading [EKR] 3.0 mm, EKR 4.5 mm, total corneal refractive power (TCRP) 2.0 mm ring, TCRP 3.0 mm zone, TCRP 4.0 mm zone). The SIA was analyzed for each parameter. Results: On the double-angle polar plot, the summated vector mean values of SIA determined by the automated keratometer and Scheimpflug anterior K were 0.28 diopter (axis: 177°) and 0.37 diopter (axis: 175°) in with-the-rule (WTR) astigmatism; 0.03 diopter (axis: 156°) and 0.18 diopter (axis: 177°) in oblique astigmatism; 0.15 diopter (axis: 96°) and 0.17 diopter (axis: 73°) in against-the-rule (ATR) astigmatism. The mean SIAs on the total cornea ranged from 0.31 to 0.42 diopter in WTR astigmatism; from 0.16 to 0.27 diopter in oblique astigmatism; from 0.04 to 0.11 diopter in ATR astigmatism. Mean magnitude SIA ranged from 0.41 to 0.46 diopter on anterior corneal surface and 0.50 to 0.62 diopter on total cornea. J0 and J45 of the posterior cornea showed no significant changes after cataract surgery, and the changes in J0 and J45 did not show any statistical differences between the anterior and total cornea (all p > 0.05). Conclusions: There were no differences in the summed vector mean values of SIA between the anterior cornea and the total cornea.

Cite

CITATION STYLE

APA

Yoon, Y. chae, Ha, M., & Whang, W. J. (2021). Comparison of surgically induced astigmatism between anterior and total cornea in 2.2 mm steep meridian incision cataract surgery. BMC Ophthalmology, 21(1). https://doi.org/10.1186/s12886-021-02131-x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free