First ptychographic X-ray computed tomography experiment on the NanoMAX beamline

9Citations
Citations of this article
24Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Ptychographic X-ray computed tomography is a quantitative three-dimensional imaging technique offered to users of multiple synchrotron radiation sources. Its dependence on the coherent fraction of the available X-ray beam makes it perfectly suited to diffraction-limited storage rings. Although MAX IV is the first, and so far only, operating fourth-generation synchrotron light source, none of its experimental stations is currently set up to offer this technique to its users. The first ptychographic X-ray computed tomography experiment has therefore been performed on the NanoMAX beamline. From the results, information was gained about the current limitations of the experimental setup and where attention should be focused for improvement. The extracted parameters in terms of scanning speed, size of the imaged volume and achieved resolutions should provide a baseline for future users designing nano-Tomography experiments on the NanoMAX beamline.

References Powered by Scopus

MARCHING CUBES: A HIGH RESOLUTION 3D SURFACE CONSTRUCTION ALGORITHM.

8353Citations
N/AReaders
Get full text

Simultaneous algebraic reconstruction technique (SART): A superior implementation of the art algorithm

1503Citations
N/AReaders
Get full text

High-resolution scanning X-ray diffraction microscopy

1148Citations
N/AReaders
Get full text

Cited by Powered by Scopus

NanoMAX: The hard X-ray nanoprobe beamline at the MAX IV Laboratory

48Citations
N/AReaders
Get full text

Design and performance of a dedicated coherent X-ray scanning diffraction instrument at beamline NanoMAX of MAX IV

22Citations
N/AReaders
Get full text

X-ray in-line holography and holotomography at the NanoMAX beamline

11Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Kahnt, M., Sala, S., Johansson, U., Bjorling, A., Jiang, Z., Kalbfleisch, S., … Thanell, K. (2020). First ptychographic X-ray computed tomography experiment on the NanoMAX beamline. Journal of Applied Crystallography, 53, 1444–1451. https://doi.org/10.1107/S160057672001211X

Readers' Seniority

Tooltip

Researcher 10

59%

PhD / Post grad / Masters / Doc 6

35%

Lecturer / Post doc 1

6%

Readers' Discipline

Tooltip

Physics and Astronomy 11

73%

Chemistry 2

13%

Materials Science 1

7%

Energy 1

7%

Save time finding and organizing research with Mendeley

Sign up for free