Does the extent of osteonecrosis affect the survival of hip resurfacing?

32Citations
Citations of this article
30Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: The effect of the extent of osteonecrosis on the survival of hip resurfacing for osteonecrosis of the femoral head (ONFH) has not been well documented, but is a potentially important variable in the decision to perform resurfacing. Questions/purposes: We examined (1) the relationship between the volume of osteonecrosis in the femoral head before surgery and the extent of the residual necrotic bone after femoral head machining, (2) how the extent of the residual necrotic bone relative to the resurfaced femoral head (after femoral head machining) affected the survival of total hip resurfacing for patients with ONFH, and (3) how the extent of the necrotic bone relative to the entire femoral head (before femoral head machining) affected the survival and clinical outcome scores of patients who underwent total hip resurfacing. Methods: Thirty-three patients (39 hips) who underwent hip resurfacing were reviewed after a mean followup of 8 years. The extent of osteonecrosis in the femoral head and residual osteonecrosis in the implant bony bed after femoral head machining were estimated using a three-dimensional MRI-based templating system. Results: There was a statistically significant difference in the extent of osteonecrosis before and after femoral head machining, although the two were well correlated (r = 0.97). The mean percentage of osteonecrosis in the implant bony bed after femoral head machining was 5% smaller than that relative to the entire femoral head (range, -9% to 15%). There were no significant differences in implant survival between groups with small and large osteonecrosis classified by either the total amount of osteonecrosis before surgery or residual osteonecrosis after femoral head machining. Conclusion: The extent of osteonecrosis in the femoral head significantly decreased after femoral head machining. Neither the residual osteonecrosis volume in the implant bony bed after femoral head machining nor the total amount of osteonecrosis before femoral head machining had significant influence on the survival of hip resurfacing. Level of Evidence: Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence. © 2013 The Association of Bone and Joint Surgeons®.

Cite

CITATION STYLE

APA

Nakasone, S., Takao, M., Sakai, T., Nishii, T., & Sugano, N. (2013). Does the extent of osteonecrosis affect the survival of hip resurfacing? Clinical Orthopaedics and Related Research, 471(6), 1926–1934. https://doi.org/10.1007/s11999-013-2833-x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free