Nasotracheal tube placement over the fibreoptic laryngoscope

20Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

We have assessed the effectiveness of three tracheal tube rotational movements in assisting nasotracheal tube placement over the fibreoptic laryngoscope. Ninety ASA grade 1 or 2 oral surgery patients undergoing fibreoptic nasotracheal intubation under general anaesthesia were studied. After the fibrescope had been positioned in the trachea, patients were randomly allocated to one of three groups. In group 1, no rotation was used and the tube was advanced towards the trachea in the neutral position. In group 2, the tube was rotated by 90° anticlockwise. In group 3, the tube was rotated by 180° anticlockwise, then rotated back to 90° anticlockwise (overcorrected rotation). If resistance to the advance was encountered, up to two more attempts were allowed, after further rotational manoeuvers had been made, in accordance with a standard, graduated sequence. There were significantly more successful tube placements at the first attempt in groups 2 and 3 (93% and 100% respectively) than in group 1 (63%). It is therefore recommended that 90° anticlokcwise or overcorrected 90° anticlockwise tube rotation is used to facilitate nasotracheal tube placement during fibreoptic intubation.

Cite

CITATION STYLE

APA

Hughes, S., & Smith, J. E. (1996). Nasotracheal tube placement over the fibreoptic laryngoscope. Anaesthesia, 51(11), 1026–1028. https://doi.org/10.1111/j.1365-2044.1996.tb14996.x

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free