One common approach for anti-erosion measures in low pressure steam turbines is to equip a hollow stator vane with slots on the airfoil surface in order to remove the water film by suction and consequently reduce the amount of secondary droplets. The purpose of this paper is to build an understanding of the predomin-ant effects in fluid-film interaction and to examine the suitability of modern numerical methods for the design process of such slots. The performance of a suction slot in terms of collection rate and air leakage is investigated numerically in a flat-plate setup with upstream injection of water. In order to model the relevant phenomena ( film transport, edge stripping of dro-plets, transport of droplets in the surrounding fluid, wall impingement of droplets) an unsteady Eulerian-Lagrangian simulation setup is applied. The accuracy of the numerical approach is assessed by comparison with experimental measurements. The comparison of four cases with the measured data demonstrates that the chosen simulation approach is able to predict the main features of film flow and interaction with the surrounding fluid. The collection rate as well as fluid film properties show the same qualitative dependency from water mass flow rate and air velocity.
CITATION STYLE
Bohn, D., Uno, T., Yoshida, T., Betcher, C., Fronheiser, J., & Weidtmann, K. (2021). Numerical and experimental study of droplet-film-interaction for low pressure steam turbine erosion protection applications. Journal of the Global Power and Propulsion Society, 5, 90–103. https://doi.org/10.33737/jgpps/140173