Comparison of the Mapleson C circuit, 500 ml and 1.6 l self-inflating bags for delivering guideline-compliant ventilation during simulated adult cardiopulmonary resuscitation

  • Sherren P
  • Lewinsohn A
  • Jovaisa T
  • et al.
N/ACitations
Citations of this article
2Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: Despite all the research and education that has gone into the field of cardiopulmonary resuscitation (CPR), survival rates remain bleak. A significant problem has been the discrepancy between teachings and witnessed clinical practice. As a result of this, and the deleterious outcomes associated with hyperventilation, we conducted a manikin-based study to evaluate three different ventilating devices and their ability to provide guideline-compliant ventilation during simulated adult CPR. Methods: A simulated cardiac arrest scenario was undertaken by 33 healthcare professionals (alpha = 0.05, power = 80%). Participants were asked to ventilate a simulated cardiac arrest patient for a period of 1 minute with all three devices, during which time various ventilatory parameters were recorded using a spirometer. The devices investigated were the Mapleson C circuit, adult (1.6 l) and paediatric (500 ml) self-inflating bags. P <0.01 was deemed statistical significant, due to multiple comparisons. Results: The paediatric self-inflating bag performed best, with signifi - cant improvement in the mean minute ventilation (P = 0.003), tidal volume (P <0.001) and peak airway pressure (P <0.001). Despite the significant differences, the paediatric self-inflating bag still delivered a mean minute ventilation of 7.01 l/minute, which still exceeds the Resuscitation Council's suggested 5 l/minute. See Table 1. (Table presented) Conclusions: Participants were found to be hyperventilating simulated cardiac arrest patients with all devices. The paediatric self-inflating bags delivered the most guideline-compliant ventilation and its use in adult CPR may be a simple measure to ensure delivery of more guidelineconsistent ventilation.

Cite

CITATION STYLE

APA

Sherren, P., Lewinsohn, A., Jovaisa, T., & Wijayatilake, S. (2011). Comparison of the Mapleson C circuit, 500 ml and 1.6 l self-inflating bags for delivering guideline-compliant ventilation during simulated adult cardiopulmonary resuscitation. Critical Care, 15(S1). https://doi.org/10.1186/cc9710

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free