Shim-on-Chip Design for Microfluidic NMR Detectors

12Citations
Citations of this article
26Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

In this contribution we present a novel system for shimming capillary samples such as used in microfluidic NMR probe heads. Due to the small sample size, shimming microliter samples using regular shim coils is complicated. Here we demonstrate the use of a series of parallel wires placed perpendicular to B0 as a Shim-on-Chip shim system. This is achieved by placing a ribbon flat cable horizontally over the NMR detector, in our case a stripline. The current through each wire of the ribbon cable can be controlled independently employing a 16 channel DAC. This makes for a simple, cheap, and easy to construct alternative to regular shim systems. The Shim-on-Chip is, nevertheless, quite flexible in creating a magnetic field which matches the inhomogeneity of the magnet in one dimension. The capillary sample geometry is well suited for this type of shimming since its length is much larger than its width. With this Shim-on-Chip system we have reached line widths of 2.2 Hz (at 50%) and 27 Hz (at 0.55%) on a 144 MHz NMR spectrometer without any other room temperature shims. Unlike regular shims, the Shim-on-Chip is located inside the NMR probe. It is always centered on the NMR sample, because of this the shims have an intuitive effect on the line shape. Therefore, the manual shimming is simpler when compared to a regular shim system, as it is difficult to position a microliter sample in the exact center of the shim coils. We furthermore demonstrate the use of a Shim-on-Chip method in a 400 MHz Rapid-Melt DNP system. Decent line widths were achieved even for a sample which is located off-center inside the NMR magnet.

References Powered by Scopus

Differential Evolution - A Simple and Efficient Heuristic for Global Optimization over Continuous Spaces

23989Citations
N/AReaders
Get full text

Magnet field profiling: Analysis and correcting coil design

347Citations
N/AReaders
Get full text

Electrical current shims for correcting magnetic fields

185Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Recent Advances on Sorting Methods of High-Throughput Droplet-Based Microfluidics in Enzyme Directed Evolution

31Citations
N/AReaders
Get full text

Microfluidic quantum sensing platform for lab-on-a-chip applications

29Citations
N/AReaders
Get full text

Modular transmission line probes for microfluidic nuclear magnetic resonance spectroscopy and imaging

22Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Van Meerten, S. G. J., Van Bentum, P. J. M., & Kentgens, A. P. M. (2018). Shim-on-Chip Design for Microfluidic NMR Detectors. Analytical Chemistry, 90(17), 10134–10138. https://doi.org/10.1021/acs.analchem.8b02284

Readers over time

‘18‘19‘20‘21‘22‘23‘24‘2502468

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 14

67%

Researcher 4

19%

Professor / Associate Prof. 3

14%

Readers' Discipline

Tooltip

Chemistry 9

60%

Engineering 3

20%

Computer Science 2

13%

Materials Science 1

7%

Save time finding and organizing research with Mendeley

Sign up for free
0