We assessed the relationships between changes in lung compliance, lung volumes and dynamic hyperinflation in patients with emphysema who underwent bronchoscopic treatment with nitinol coils (coil treatment) (n=11) or received usual care (UC) (n=11). Compared with UC, coil treatment resulted in decreased dynamic lung compliance (CLdyn) (p=0.03) and increased endurance time (p=0.010). The change in CLdyn was associated with significant improvement in FEV 1 and FVC, with reduction in residual volume and intrinsic positive end-expiratory pressure, and with increased inspiratory capacity at rest/and at exercise. The increase in end-expiratory lung volume (EELV) during exercise (EELVdyn-ch =EELVisotime EELVrest) demonstrated significant attenuation after coil treatment (p=0.02).
CITATION STYLE
Makris, D., Leroy, S., Pradelli, J., Benzaquen, J., Guenard, H., Perotin, J. M., … Marquette, C. H. (2018). Changes in dynamic lung mechanics after lung volume reduction coil treatment of severe emphysema. Thorax, 73(6), 584–586. https://doi.org/10.1136/thoraxjnl-2017-210118