Design Development of the SMARTCLIC®/CLICWISE® Injection Device for Self-Administered Subcutaneous Therapies: Findings from Usability and Human Factor Studies

3Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Introduction: An easy-to-use, multiuse, single-patient, electromechanical autoinjector, the SMARTCLIC®/CLICWISE® injection device, was recently developed to improve the self-administration options available to patients with chronic inflammatory disease treated with biologic agents. An extensive series of studies were conducted to guide the design and development of this device and to ensure its safety and effectiveness. Methods: Participants in two user preference studies and three formative human factor (HF) studies evaluated evolving iterations of the autoinjector device, dose dispenser cartridge, graphical user interface, and informational materials; participants in a summative HF test subsequently assessed the final proposed commercially representative product. In the user preference studies, rheumatologists and patients with chronic inflammatory disease, interviewed online and in-person, provided feedback on the design and functionality of four prototypes. In the HF studies, the safety, effectiveness, and usability of adapted prototypes were assessed under simulated-use conditions by patients with chronic inflammatory disease, caregivers, and healthcare professionals (HCPs). The safety and effectiveness of the final refined device and system were confirmed in a summative HF test by patients and HCPs in simulated-use scenarios. Results: Rheumatologists (n = 204) and patients (n = 39) interviewed in the two user preference studies provided feedback on the device size, feature ergonomics, and usability that guided prototype development in the subsequent formative HF studies. Observations from patients, caregivers, and HCPs (n = 55) participating in the latter studies yielded additional critical design revisions that culminated in development of the final device and system. Of 106 injection simulations conducted in the summative HF test, all resulted in successful medication delivery, and no potential harms were associated with injection-related use events. Conclusion: Findings from this research facilitated development of the SmartClic/ClicWise autoinjector device and demonstrated that it could be used safely and effectively by participants representative of the intended-use population of patients, lay caregivers, and HCPs.

Cite

CITATION STYLE

APA

Berman, K., Moss, S., Holden-Theunissen, B., Satou, N., Okada, K., Latymer, M., & Antalfy, A. (2023). Design Development of the SMARTCLIC®/CLICWISE® Injection Device for Self-Administered Subcutaneous Therapies: Findings from Usability and Human Factor Studies. Advances in Therapy, 40(7), 3070–3086. https://doi.org/10.1007/s12325-023-02512-2

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free