Reproducibility of goniometric measurement of the knee in the in-hospital phase following total knee arthroplasty

97Citations
Citations of this article
142Readers
Mendeley users who have this article in their library.

Abstract

Background. The objective of the present study was to assess interobserver reproducibility (in terms of reliability and agreement) of active and passive measurements of knee RoM using a long arm goniometer, performed by trained physical therapists in a clinical setting in total knee arthroplasty patients, within the first four days after surgery. Methods. Test-retest analysis. Setting: University hospital departments of orthopaedics and physical therapy. Participants: Two experienced physical therapists assessed 30 patients, three days after total knee arthroplasty. Main outcome measure: RoM measurement using a long-arm (50 cm) goniometer. Agreement was calculated as the mean difference between observers ± 95% CI of this mean difference. The intraclass correlation coefficient (ICC) was calculated as a measure of reliability, based on two-way random effects analysis of variance. Results. The lowest level of agreement was that for measurement of passive flexion with the patient in supine position (mean difference 1.4°; limits of agreement 16.2° to 19° for the difference between the two observers. The highest levels of agreement were found for measurement of passive flexion with the patient in sitting position and for measurement of passive extension (mean difference 2.7°; limits of agreement -6.7 to 12.1 and mean difference 2.2°; limits of agreement -6.2 to 10.6 degrees, respectively). The ability to differentiate between subjects ranged from 0.62 for measurement of passive extension to 0.89 for measurements of active flexion (ICC values). Conclusion. Interobserver agreement for flexion as well as extension was only fair. When two different observers assess the same patients in the acute phase after total knee arthroplasty using a long arm goniometer, differences in RoM of less than eight degrees cannot be distinguished from measurement error. Reliability was found to be acceptable for comparison on group level, but poor for individual comparisons over time. © 2007 Lenssen et al; licensee BioMed Central Ltd.

References Powered by Scopus

STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT

42327Citations
N/AReaders
Get full text

Assessing health status and quality-of-life instruments: Attributes and review criteria

2050Citations
N/AReaders
Get full text

Clinical measurement of range of motion. Review of goniometry emphasizing reliability and validity

672Citations
N/AReaders
Get full text

Cited by Powered by Scopus

Accuracy and reliability of knee goniometry methods

150Citations
N/AReaders
Get full text

Reliability of knee joint range of motion and circumference measurements after total knee arthroplasty: Does tester experience matter?

125Citations
N/AReaders
Get full text

Reliability of a smartphone-based goniometer for knee joint goniometry

104Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Lenssen, A. F., Van Dam, E. M., Crijns, Y. H. F., Verhey, M., Geesink, R. J. T., Van Den Brandt, P. A., & De Bie, R. A. (2007). Reproducibility of goniometric measurement of the knee in the in-hospital phase following total knee arthroplasty. BMC Musculoskeletal Disorders, 8. https://doi.org/10.1186/1471-2474-8-83

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 70

72%

Researcher 15

15%

Lecturer / Post doc 7

7%

Professor / Associate Prof. 5

5%

Readers' Discipline

Tooltip

Medicine and Dentistry 52

50%

Nursing and Health Professions 33

32%

Sports and Recreations 11

11%

Engineering 7

7%

Article Metrics

Tooltip
Social Media
Shares, Likes & Comments: 5

Save time finding and organizing research with Mendeley

Sign up for free