Release kinetics of the model protein FITC-BSA from different polymer-coated bovine bone substitutes

7Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Controlled release of proteins bound to conventional bone substitutes is still insufficient. Therefore, this study evaluates in-vitro release kinetics of the model protein FITC-BSA (fluorescein conjugated bovine serum albumine) from insoluble bovine collagenous bone matrices (ICBM) with different polymer coatings. Analyzes aim at comparing FITC-BSA release from uncoated versus coated ICBM over time to find bone substitute coatings with consistent release profiles. Methods: Release kinetics of FITC-BSA from uncoated as well as coated ICBM with five different polymers (RESOMER R 203 H, RG 503 H, RG 504 H, RG 505, L 206 S) were measured over a period of 11 days (d). Measurements were conducted after 6 h (h), 12 h, 24 h, 3 d, 5 d, 7 d, 9 d and 11 d with six samples for each coated ICBM. Two groups were formed (1) with and (2) without medium change at times of measurement. For each group ANOVA with post-hoc Bonferroni testing was used. Scanning electron microscopy assessed morphologic differences between ICBM coating. Results: In group 1 approx. 70% of FITC-BSA release from uncoated ICBM occurred after 6 h compared to approx. 50% in group 2. Only polymers with medium inherent viscosity, i.e. RESOMER RG 503 H, constantly showed significantly more FITC-BSA release throughout 11 d than uncoated ICBM (p = 0.007). The same was found for group 2 (p = 0.005). No significant differences between PLA and PLGA polymers were found. Scanning electron microscopy results indicate a weak adhesion of polymer coatings to ICBM explaining its rather weak retentive effect on overall FITC-BSA release. Conclusions: Medium molecular size polymers reduce the overall released FITC-BSA from ICBM over time. In clinical practice these polymers may prove ideal for bone substitute materials.

Cite

CITATION STYLE

APA

Lommen, J., Schorn, L., Landers, A., Holtmann, H., Berr, K., Kübler, N. R., … Depprich, R. (2019). Release kinetics of the model protein FITC-BSA from different polymer-coated bovine bone substitutes. Head and Face Medicine, 15(1). https://doi.org/10.1186/s13005-019-0211-y

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free