Whole-heart coronary MRA with 100% respiratory gating efficiency: Self-navigated three-dimensional retrospective image-based motion correction (TRIM)

93Citations
Citations of this article
105Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose To develop a three-dimensional retrospective image-based motion correction technique for whole-heart coronary MRA with self-navigation that eliminates both the need to setup a diaphragm navigator and gate the acquisition. Methods The proposed technique uses one-dimensional self-navigation to track the superior-inferior translation of the heart, with which the acquired three-dimensional radial k-space data is segmented into different respiratory bins. Respiratory motion is then estimated in image space using an affine transform model and subsequently this information is used to perform efficient motion correction in k-space. The performance of the proposed technique on healthy volunteers is compared with the conventional navigator gating approach as well as data binning using diaphragm navigator. Results The proposed method is able to reduce the imaging time to 7.1±0.5 min from 13.9±2.6 min with conventional navigator gating. The scan setup time is reduced as well due to the elimination of the navigator. The proposed method yields excellent image quality comparable with either conventional navigator gating or the navigator binning approach. Conclusion We have developed a new respiratory motion correction technique for coronary MRA that enables 1 mm 3 isotropic resolution and whole-heart coverage with 7 min of scan time. Further tests on patient population are needed to determine its clinical usage. © 2013 Wiley Periodicals, Inc.

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Pang, J., Bhat, H., Sharif, B., Fan, Z., Thomson, L. E. J., Labounty, T., … Li, D. (2014). Whole-heart coronary MRA with 100% respiratory gating efficiency: Self-navigated three-dimensional retrospective image-based motion correction (TRIM). Magnetic Resonance in Medicine, 71(1), 67–74. https://doi.org/10.1002/mrm.24628

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 58

73%

Researcher 17

22%

Professor / Associate Prof. 2

3%

Lecturer / Post doc 2

3%

Readers' Discipline

Tooltip

Engineering 40

56%

Physics and Astronomy 14

20%

Medicine and Dentistry 14

20%

Computer Science 3

4%

Save time finding and organizing research with Mendeley

Sign up for free