Efficacy of a One-Piece Aberration Neutral Hydrophobic Acrylic Toric Intraocular Lens

2Citations
Citations of this article
2Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To assess the refractive outcomes, intraocular centration and rotational stability of the enVista toric intraocular lens (IOL). Patients and Methods: This study was a prospective, multi-centre, double-masked, partially randomized and partially controlled clinical trial. A total of 191 participants were implanted with toric IOL (1.25, 2.00, or 2.75D) or non-toric IOL (control). The lowest range of corneal astigmatic eyes were randomized to 1.25D toric or control. Higher astigmatic powers were allocated to the treatment arm. Subjects were assessed immediately postoperatively, 1–2 (V1), 7–14 (V2), 30–60 (V3) and 120–180 (V4) days postoperatively. Unaided (UDVA) and distance corrected visual acuity (CDVA), manifest refraction and corneal curvature were assessed. Vector analysis was used to calculate surgically induced refractive correction (SIRC), correction ratio (CR), error magnitude (EM) and error vector (EV). Slit-lamp photography was used to measure centration and rotational stability. Results: UDVA was better in the low toric IOL group in comparison with the control group at V4 (p<0.001). There was an undercorrection in the control group, whereas the average CR for all toric subjects was 1.00 ± 0.32: V2, 0.98 ± 0.34: V3 and 0.98 ± 0.35: V4. The absolute IOL rotational stability in comparison to the position of the IOL at V1 was 1.35° ± 0.97°: V2, 1.35° ± 1.07°: V3 and 1.38° ± 1.25°: V4. Decentration was generally inferior (V1: 0.04 ± 0.22mm, V2: 0.05± 0.20mm, V3: 0.08 ± 0.22mm, V4: 0.04 ± 0.21mm) and nasal (V1: 0.19 ± 0.23mm, V2: 0.20 ± 0.20mm, V3: 0.20 ± 0.21mm, V4: 0.17 ± 0.22mm). Conclusion: Participants with low levels of corneal astigmatism achieved superior vision and refractive outcomes in the low toric group over the control. Moderate and high levels of astigmatism achieved excellent refractive outcomes. The toric IOL demonstrated high levels of both rotational and centrational stability.

Author supplied keywords

Cite

CITATION STYLE

APA

Buckhurst, P. J., Lau, G., Williams, J. I., & Packer, M. (2022). Efficacy of a One-Piece Aberration Neutral Hydrophobic Acrylic Toric Intraocular Lens. Clinical Ophthalmology, 16, 3763–3774. https://doi.org/10.2147/OPTH.S386551

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free