The effect of implant placement torque on crestal bone remodeling after 1 year of loading

27Citations
Citations of this article
60Readers
Mendeley users who have this article in their library.

Abstract

Purpose: The aim of this study was to evaluate and compare crestal bone levels (CBLs) after 1 year of loading of self-tapping bone condensing implants placed with high insertion torque (IT) compared to those placed with lower IT. Materials and methods: A retrospective chart review of 66 consecutive patients who received at least one self-tapping bone condensing implant and were in function for at least 1 year was conducted. On the basis of intrasurgical notes documenting the implant IT, the patient population was divided into group A (implant IT, >55 Ncm) and group B (IT, <55 Ncm). Radiographs taken immediately after insertion and during annual follow-up appointments were evaluated for detecting crestal bone loss. The relationship between IT and crestal bone loss, bone density, and jaw location were analyzed, and a P-value of 0.05 was considered to be statistically significant. Results: A total of 113 self-tapping bone condensing NobelActive™ implants were placed. The average follow-up period from the placement of the implant restoration was 12.87 (±4.83) months. Six implants were classified as failures resulting in overall survival rate of 94.6%. Implants in group A had a mean IT of 67.35 ± 4.0 Ncm, whereas implants in the group B had a mean IT of 37.9 ± 12.62 Ncm. Implants in group A had statistically significant crestal bone loss compared to implants in group B (0.95 ± 1.60 and 0.18 ± 0.68 mm, respectively). Group A implants placed in the mandible showed significantly more pronounced crestal bone loss (2.12 ± 1.99 mm) compared to those placed in the maxilla (0.25 ± 0.65 mm; P<0.05); however, this was not the case in group B implants. Conclusion: Implants inserted with high IT (>55 Ncm) showed more peri-implant bone remodeling than implants inserted with a less assertive IT (<55 Ncm). Bone density and jaw location affect IT and CBLs.

Cite

CITATION STYLE

APA

Aldahlawi, S., Demeter, A., & Irinakis, T. (2018). The effect of implant placement torque on crestal bone remodeling after 1 year of loading. Clinical, Cosmetic and Investigational Dentistry, 10, 203–209. https://doi.org/10.2147/CCIDE.S174895

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free