Use of conventional cardiac troponin assay for diagnosis of non-ST-elevation myocardial infarction: 'The Ottawa Troponin Pathway'

4Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

Abstract

Background Serial conventional cardiac troponin (cTn) measurements 6 9 hours apart are recommended for non-ST-elevation MI (NSTEMI) diagnosis. We sought to develop a pathway with 3-hour changes for major adverse cardiac event (MACE) identification and assess the added value of the HEART [History, Electrocardiogram (ECG), Age, Risk factors, Troponin] score to the pathway. Methods We prospectively enrolled adults with NSTEMI symptoms at two-large emergency departments (EDs) over 32-months. Patients with STEMI, unstable angina and one cTn were excluded. We collected baseline characteristics, Siemens Vista conventional cTnI at 0, 3 or 6-hours after ED presentation; HEART score predictors; disposition and ED length of stay (LOS). Adjudicated primary outcome was 15-day MACE (acute MI, revascularization, or death due to cardiac ischemia/unknown cause). We analyzed multiples of 99th percentile cut-off cTnI values (45, 100 and 250ng/L). Results 1,683 patients (mean age 64.7 years; 55.3% female; median LOS 7-hours; 88 patients with 15-day MACE) were included. 1,346 (80.0%) patients with both cTnI45 ng/L; and 155 (9.2%) of the 213 patients with one value100ng/L but both<250ng/L or 20% change did not suffer MACE. Among 124 patients (7.4%) with one of the two values>45ng/L but<100ng/L based on 3 or 6-hour cTnI, one patient with absolute change<10ng/L and 6 of the 19 patients with20ng/L were diagnosed with NSTEMI (patients with Δ10-19ng/L between first and second cTnI had third one at 6-hours). Based on the results, we developed the Ottawa Troponin Pathway (OTP) with a 98.9% sensitivity (95% CI 93.8 100%) and 94.6%specificity (95% CI 93.3 95.6%). Addition of the HEART score improved the sensitivity to 100% (95% CI 95.9 100%) and decreased the specificity to 26.5% (95% CI 24.3 28.7%). Conclusion The OTP with conventional cTnI 3-hours apart, should lead to better NSTEMI identification particularly those with values >99th percentile, standardize management and reduce the ED LOS.

Cite

CITATION STYLE

APA

Thiruganasambandamoorthy, V., Stiell, I. G., Chaudry, H., Mukarram, M., Booth, R. A., Toarta, C., … Taljaard, M. (2020). Use of conventional cardiac troponin assay for diagnosis of non-ST-elevation myocardial infarction: “The Ottawa Troponin Pathway.” PLoS ONE, 15(1). https://doi.org/10.1371/journal.pone.0226892

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free