Use of a dry-plasma collection device to overcome problems with storage and transportation of blood samples for epidemiology studies in developing countries

6Citations
Citations of this article
25Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Studies are difficult in areas lacking modern facilities due to the inability to reliably collect, store, and ship samples. Thus, we sought to evaluate the use of a dry plasma collection device for seroepidemiology studies. Plasma was obtained by fingerstick using a commercial dry plasma collection device (Chemcard Plasma Collection Device) and serum (venipuncture) from individuals in Kazakhstan. Plasma samples were air dried for 15 min and then stored desiccated in foil zip-lock pouches at 4 to 6°C and subsequently shipped to the United States by air at ambient temperature. Serum samples remained frozen at -20°C until assayed. Helicobacter pylori status was determined by enzyme-linked immunosorbent assay (HM-CAP EIA) for the dry plasma and the serum samples. The results were concordant in 250 of the 289 cases (86.5%). In 25 cases (8.6%), the dry plasma samples gave indeterminate results and could not be retested because only one sample was collected. Five serum samples were positive, and the corresponding dry plasma samples were negative; one serum sample was negative, and the corresponding plasma sample was positive. The relative sensitivity and specificity of the Chemcard samples to serum were 97.6 and 97.9%, respectively, excluding those with indeterminate results. Repeated freeze-thawing had no adverse effect on the accuracy of the test. We found the dry plasma collection device to provide an accurate and practical alternative to serum when venipuncture may be difficult or inconvenient and sample storage and handling present difficulties, especially for seroepidemiologic studies in rural areas or developing countries and where freeze-thawing may be unavoidable.

Cite

CITATION STYLE

APA

Nurgalieva, Z. Z., Almuchambetova, R., Machmudova, A., Kapsultanova, D., Osato, M. S., Peacock, J., … Zhangabylov, A. (2000). Use of a dry-plasma collection device to overcome problems with storage and transportation of blood samples for epidemiology studies in developing countries. Clinical and Diagnostic Laboratory Immunology, 7(6), 882–884. https://doi.org/10.1128/CDLI.7.6.882-884.2000

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free