In vivo 31P MR spectroscopic imaging of the human prostate at 7 T: Safety and feasibility

37Citations
Citations of this article
42Readers
Mendeley users who have this article in their library.

Abstract

31P MR spectroscopic imaging of the human prostate provides information about phosphorylated metabolites that could be used for prostate cancer characterization. The sensitivity of a magnetic field strength of 7 T might enable 3D 31P MR spectroscopic imaging with relevant spatial resolution in a clinically acceptable measurement time. To this end, a 31P endorectal coil was developed and combined with an eight-channel 1H body-array coil to relate metabolic information to anatomical location. An extensive safety validation was performed to evaluate the specific absorption rate, the radiofrequency field distribution, and the temperature distribution of both coils. This validation consisted of detailed Finite Integration Technique simulations, confirmed by MR thermometry and B 1+ measurements in a phantom and in vivo temperature measurements. The safety studies demonstrated that the presence of the 31P endorectal coil had no influence on the specific absorption rate levels and temperature distribution of the external eight-channel 1H array coil. To stay within a 10 g averaged local specific absorption rate of 10 W/kg, a maximum time-averaged input power of 33 W for the 1H array coil was allowed. For transmitting with the 31P endorectal coil, our safety limit of less than 1°C temperature increase in vivo during a 15-min MR spectroscopic imaging experiment was reached at a time-averaged input power of 1.9 W. With this power setting, a second in vivo measurement was performed on a healthy volunteer. Using adiabatic excitation, 3D 31P MR spectroscopic imaging produced spectra from the entire prostate in 18 min with a spatial resolution of 4 cm3. The spectral resolution enabled the separate detection of phosphocholine, phosphoethanolamine, inorganic phosphate, and other metabolites that could play an important role in the characterization of prostate cancer. Copyright © 2012 Wiley Periodicals, Inc.

Author supplied keywords

References Powered by Scopus

The Virtual Family - Development of surface-based anatomical models of two adults and two children for dosimetric simulations

1290Citations
N/AReaders
Get full text

Dielectric constants of some organic solvent-water mixtures at various temperatures

1217Citations
N/AReaders
Get full text

A precise and fast temperature mapping using water proton chemical shift

929Citations
N/AReaders
Get full text

Cited by Powered by Scopus

MRI at 7 Tesla and above: Demonstrated and potential capabilities

154Citations
N/AReaders
Get full text

Multiparametric magnetic resonance imaging in prostate cancer management: Current status and future perspectives

82Citations
N/AReaders
Get full text

W(h)ither human cardiac and body magnetic resonance at ultrahigh fields? technical advances, practical considerations, applications, and clinical opportunities

42Citations
N/AReaders
Get full text

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Cite

CITATION STYLE

APA

Kobus, T., Bitz, A. K., Van Uden, M. J., Lagemaat, M. W., Rothgang, E., Orzada, S., … Scheenen, T. W. J. (2012). In vivo 31P MR spectroscopic imaging of the human prostate at 7 T: Safety and feasibility. Magnetic Resonance in Medicine, 68(6), 1683–1695. https://doi.org/10.1002/mrm.24175

Readers' Seniority

Tooltip

PhD / Post grad / Masters / Doc 20

65%

Researcher 9

29%

Professor / Associate Prof. 2

6%

Readers' Discipline

Tooltip

Engineering 13

41%

Physics and Astronomy 8

25%

Medicine and Dentistry 8

25%

Agricultural and Biological Sciences 3

9%

Save time finding and organizing research with Mendeley

Sign up for free