Augmentation index assessed by applanation tonometry is elevated in Marfan syndrome

19Citations
Citations of this article
31Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: To examine whether augmentation index (AIx) is increased in Marfan syndrome (MFS) and associated with increased aortic root size, and whether a peripheral-to-central generalised transfer function (GTF) can be applied usefully in MFS. Methods: 10 MFS patients and 10 healthy controls (matched for sex, age and height) were studied before and after 400 μg sub-lingual GTN. Arterial waveforms were recorded using applanation tonometry. AIx and pulse pressure (PP) were determined for the radial and carotid arteries. Pulse wave velocity (PWV) was measured between carotid and femoral arteries. GTFs were generated to examine the relationship between radial and carotid waveforms. Results: AIx was greater in MFS compared to controls at radial (mean -31.4 (SD 14.3)% v -50.2(15.6)%, p = 0.003) and carotid (-7.6(11.2)% v -23.7(12.7)%, p = 0.004) sites. Baseline PP at all measurement sites, and PWV, did not differ between subject groups. Multivariate analysis demonstrated that PWV and carotid AIx were positively correlated with aortic root size (p < 0.001 and p = 0.012 respectively), independent of the presence of MFS. PP was not associated with aortic root size. GTN caused similar decreases in AIx in both controls and patients. Significant differences were found in GTFs between MFS and control subjects, which changed following GTN administration. However, when an independent GTF was used to derive carotid waves from radial waves, no differences were found in the degree of error between MFS and controls. Conclusion: AIx is sensitive to the vascular abnormalities present in MFS, and may have a role as an adjunct to measurement of central PP and PWV. Differences between MFS and controls in the nature of the peripheral-to-central GTF are present, although have little effect on the pulse contour. © 2007 Payne et al; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Payne, R. A., Hilling-Smith, R. C., Webb, D. J., Maxwell, S. R., & Denvir, M. A. (2007). Augmentation index assessed by applanation tonometry is elevated in Marfan syndrome. Journal of Cardiothoracic Surgery, 2(1). https://doi.org/10.1186/1749-8090-2-43

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free